805.245.005 Date: January 10, 201710Adjustable parametersRange DefaultMAN SPEED Speed for manual driving 200 – 2500 800MAN UP/DWN Run the motor manual from the menu MOTOR UP / MOTOR DOWNDMX ADDR DMX start address 1 – 506 1TAC RANGE Tacho range 1 – 50.000 N/ASPEED MAX Maximum speed 500 – 3500 3500SP MIN UP Minimum speed UP 50 – 1000 200SP MIN DWN Minimum speed DWN 50 – 1000 200E STOP Enable/disable emergency stop ON-OFF OFFMAN SPEED and MAN UP/DWN is used for manual control of the motor.Detailed explanation of parametersMAN SPEED Speed for manual driving. Range 200 –2500MAN SPEED sets the speed for manual driving the motor.MAN UP/DWN Manuelly driving the motor.MAN UP/DWN is used for manual control of the motor.Pressing the UP button, makes the wire run up, unless the limit switch is activatedPressing the DOWN button, makes the wire run down, unless the limit switch is activatedThe winch will stop if the Emergency Switch is activatedDMX ADDR DMX start address Range 1 - 506DMX start address defines which DMX address the Winch 50 reacts on.The Winch 50 uses minimum 6 DMX channels.TAC RANGE Tacho range Range 1 – 50.000The tacho range is setting the maximum range of the Winch.SPEED MAX Maximum speed Range 500 – 3500SPEED MAX sets the maximum speed.If set to 1000, it means the motor run at 1000 RPM when DMX speed is set to full. SPEEDMAX can be used to lower the maximum speed, e.g. while learning the system.SP MIN UP Minimum speed up. Range 50 – 1000The motor minimum speed, for the up direction.The motor is allowed to run at different minimum speed for each direction; this is todifferentiate between different mechanical loads for up and down. See SP MIN DWN.Set this value to a speed where the motor will still run up at full load.SP MIN DWN Minimum speed down Range 50 - 1000The motor minimum speed, for the down direction.The motor is allowed to run at different minimum speed for each direction, this is todifferentiate between different mechanical loads for up and down, see SP MIN UP.Set this value to a speed where the motor will still run down at full load.E STOP Enable/disable emergency stop Range ON - OFFThis enables/disables the emergency stop from the software. However to get the fullfunctionality of the emergency stop a wire has to be plugged in inside the winch. See sectionon how to change the wire setting for more details.