WL400 Manual Page 70 – Revision: 10-23-20192. Steady Drip Out of FaucetPossible Reason SolutionDebris in Solenoid Inspect Solenoid for debris and clean out as needed.3. Hot Water or Steam Coming out of both the Faucet and Vent HolePossible Reason SolutionImproper tubing attachmentfrom the hot tank to faucet orvice versa.Check that the tubing is connected from tank outlets to correctfaucet attachments. Connect tubing to outlets as needed.4. Hot Water Coming out of Faucet Vent HolePossible Reason SolutionImproper tubing attachmentfrom the tank to faucet or viceversa.Verify tubing is connected properly from tank outlets to correctfaucet attachments.Hot Tank outlet hole is scaledover.Inspect and Descale Tank as needed.See Hot Tank Descaling Instructions that are included furtherbelow in this Troubleshooting Section.See instructional video on the Partner Area of the Waterlogic.comwebsite for more information.Expansion chamber is notsealed properly. Replace the Hot Tank.