WL400 Manual Page 73 ā Revision: 10-23-20197. Dispenses Hot and Cold Water at the Same TimePossible Reason SolutionHot or Cold solenoid is stuckopen.Remove Top cover.Check Hot Solenoid: Dispense cold water and visually inspect tubingfor water flow from both tanks.Check Cold Solenoid: Disconnect elbow from outlet of cold solenoid.Select hot water and dispense (quickly releasing dispensing buttonto avoid much water coming out of cold solenoid.Replace solenoid as necessary.8. No Cold Water AvailablePossible Reason SolutionClosed Water Supply Valve Open the Water Supply ValveCold Water Solenoid Valvemalfunction Inspect the valve components for proper functionality.Green Heater and CompressorSwitch on unit is off.Turn Green Heater and Compressor Switch on.I = ONLoose connection(s) on theDisplay PCBTurn power off; unplug the unit and visually inspect solenoidconnections into the Display PCB. Verify the soldering points onconnections are secure into the board.Remove the PCB to inspect the front of the board.Exhausted Filter Replace filters as needed.