1195-03009INSTALLATIONFigure 7Figure 8Figure 9(LENGTH = 8 DIAMETERS)SUPPORTLEGS (4)SUPPORTSET SCREW(2) PER LEGMOTORMOUNT(PAGE 34)LOCATION - PIPINGPREPARATIONCheck quantities and inspect all parts of yourequipment prior to beginning installation.PUMP LOCATION1. Locate pump as near as practical to theliquid supply.2. Keep supply piping short and straight tokeep pump supplied with liquid andprevent damaging cavitation.3. Pump should be accessible for serviceand inspection during operation.4. Motor must be protected from flooding.PUMP LEVELINGLevel pump by loosening set screws andadjusting leg height. (Figure 7)SUCTION ( inlet supply) ANDDISCHARGE PIPING/VALVESNOTE: Properly support supply and dischargepiping to the pump to prevent strain on thepump casing. (Figure 8)LINE SIZEUse line size equal to, or larger thanconnection size on pump, especially the inletsupply line.LINE LENGTHKeep supply line *short and straight aspossible. *Maintain a straight length of pipe atleast 8 diameters long to pump inlet. (Figure 9).To avoid up and down loops which will trap air,use as few as possible elbows, valves or othertypes of restriction.