Designer Series 2 w/ Optional BroilerInstallation and Operation ManualPG 14 OF 24M0079�07 OCTOBER 2017An ongoing program of product improvement mayrequire us to change specifications without notice.WOOD STONE CORPORATION1801 W. Bakerview Rd.Bellingham, WA 98226 USATOLL FREE 800.988.8103TEL 360.650.1111FAX 360.650.1166E-MAIL info@woodstone-corp.comwoodstone-corp.comGAS SPECIFICATIONSFACTORY SPECIFIED INDIVIDUAL BURNER MANIFOLD PRESSURES (W.C.) FORWS-DS2 MODELSNatural Gas (NG) Propane (LP)ModelSV-2Radiant BurnerOptionalBroilerSV-2Radiant BurnerOptionalBroilerWS-DS2 5" W�C� 4" W�C� 9�5" W�C� 11" W�C�This oven requires no modifications or adjustments for use at high altitudes.The installation of this appliance must conform with local codes, or in the absence of local codes, with the NationalFuel Gas Code, ANSI Z223.1 or The Natural Gas Installation Code CAN/CGA-B149.1 as applicable.SV-2 (and SV-3 if equipped) are the gas control valve(s) that operates the interior Radiant Burner(s)� The manifold pressure(s) arechecked at the outlet port on the individual gas valve�The burner manifold pressures have been adjusted and tested at the factory� A variety of factors can influence these pressures,so be sure to test the individual burner manifold pressures and adjust the valves as necessary to achieve the required pressures�NOTE: The gas valves are shipped in the ON position�GAS CONNECTIONWood Stone Designer Series 1 ovens are equipped with a 3/4-inch FNPT gas connection (see page 16 for exact location)� Havea licensed gas installer provide the hookup and test all fittings and pipe connections for leaks� Use approved gas leak detectors(soap solutions or equivalent) over and around the fittings and pipe connections� DO NOT USE FLAME TO TEST FOR LEAKS!All gas piping up to the oven must have a minimum inside diameter of 3/4", including all fittings and shut off valves, which shouldbe of the full flow type�Wood Stone recommends that the Designer Series oven be equipped with a manual, individual shutoff valve, located betweenthe oven and the main gas supply, and that this shutoff valve (supplied by others) be left readily accessible� Wood Stone alsorecommends that inspection and maintenance of the burners and gas piping connections of this appliance be performed atregularly scheduled intervals and only by professional gas appliance service agencies�Maximum inlet gas pressure must not exceed 14" W.C. (1/2 psi)MAXIMUM HOURLY BTU INPUT RATES FOR WS-MS-RFG-IR-W MODELSSee data plate for your specific model.