66-10 Color CalibrationCalibrating the Fiery SI from the Control PanelYou can calibrate the Fiery SI from the Control Panel by connecting a densitometer tothe serial port on the back of the Fiery SI, or by using AutoCal.Automatic calibrationYou can calibrate the Fiery SI without a densitometer with AutoCal.U SING AUTOMATIC CALIBRATION :1. When the Fiery SI restarts, press the Menu key when prompted to enter Setup.2. Press Run Setup.3. Scroll down to choose Calibration.4. Choose Calibrate.The Calibration Method screen appears.5. Select Copier Glass for the Calibration Method.6. When prompted to Select Target, use the up/down arrow keys to scroll through the listof target names, then choose OK.You can choose from the list of all targets on the Fiery SI hard drive. This includesseveral targets included with the Fiery SI as well as any custom targets you have loaded.7. When prompted, select Yes to print the Measurements page.This page is comprised of bands of color that will be measured by the copier and thencompared to the target calibration.After the page is printed, the Measure Page screen displays.8. Select Yes and then choose OK.9. When prompted “Position page on copier, then press OK,” place the Measurementspage on the copier glass and click OK.Position the page as you would a standard portrait copy with the top of the page at thefar edge of the copier glass. The copier scans the page on the glass, creates ameasurements table, and automatically compares it to the target you selected. It thenadjusts measurements to match the target.