Installation WorkCentre® 5900 SeriesCustomer Expectation and Installation Guide 18Electrical RequirementsGround Fault Protection is provided which meets Xerox internal safety requirements and exceeds the Industry Standards for Information TechnologyEquipment. A single power cord (see above) is required for the WorkCentre 5900 seriesSpace Requirements/ Service Space EnvelopeThe dimensions shown below provide the overall service space required, including the space to the nearest obstruction. The dimensions reflect bothtypical and hallway installations and are absolute minimums.ConfigurationMachineWidth (A)mm/inchesMachinedepth (B)mm/inchesInstall Width Required (C)mm/inchesInstall Depth Required (D)mm/inchesService Work Space (E)mm/inches Left Door AccessSpace (F)mm/inchesMoveable Fixed Moveable Fixed Moveable FixedBasic machinewithout finisher 850 / 33.5 665 / 26.2 2043 / 80.4 3043 / 119.8 1665 / 65.5 2665 / 105 100 / 4 1000 / 39.4 440 / 17Basic machinewith OfficeFinisher1470 / 57.9 665 / 26.2 2663 / 104.8 3663 / 144.2 1665 / 65.5 2665 / 105 100 / 4 1000 / 39.4 440 / 17Basic machinewith OfficeFinisher andBooklet Maker1530 / 60.2 665 / 26.2 2723 / 107.2 3723 / 146.6 1665 / 65.5 2665 / 105 100 / 4 1000 / 39.4 440 / 175945/5955Geographies: Western HemisphereLine Option Sole Use (not required but recommended)Voltage 110 -127 VACAmperage 15 AFrequency 50/60 Hz, Single PhasePower CordLength8.5 feetReceptacle NEMA part #: 5-15RGeographies: Eastern HemisphereLine Option Sole Use (not required but recommended)Voltage 220 – 240 VACAmperage 10 AFrequency 50/60 Hz, Single PhasePower CordLength2.6 metersReceptacle Requires use of a 10 ampere outlet which isstandard in most modern office buildings.Consult with local service to determine thecountry specific receptacle and confirm theexistence of this outlet in the proposedinstallation space.C (Fixed)D (Fixed)FABE880mmCDE (Fixed)