10 Error10.1 Error Message10-14159645-1CDRE-CHO-A111FS10010.1.5 Concurrent I/OError No. Data Error Message Contents4010 * Illegal relay No.XXX Line no.4020 - Illegal block No.4030 * Illegal instructionXXX Line no.4040 * Relay/register No. duplicated in OUT/GOUT or arithmetic instructionMultiple outputs are instructed to the relay orregister.XXX Line no.4050 * The relay is not usedXXX Line no.4060 * Excess STR-[-NOT] instructionsXXX Line no.4070 * Excess AND [OR] STR instructionsXXX Line no.4080 * Syntax error in CRT instructionsXXX Line no.4090 * Enter STR [-NOT] at head of block Need STR [-NOT]XXX Line no.4100 - Relay No. duplicated in TMR and CNT4110 - Excessive ladder scan-time4120 - Concurrent I/O memory is full Exceeds memory capacity (10000 steps)4130 - END instruction not found END instruction not found4140 - Wrong ladder program Position and number of PART instruction arewrong.4150 * Wrong use of GSTR, GOUTcommandsGSTR and GOUT is not used together.XXX Line no.4160 - Cannot edit system section4170 - Cannot modify/delete4180 - Depress INSERT/MODIFY/DELETEkeys4190 - Ladder program not found4200 - Cannot specify system variables($)4210 - Cannot edit line4220 - Excess TMR/CNT or arithmeticinstructionsMore than 100 TMR, CNT or arithmeticinstruction used4230 - Syntax error in TMR/CNT instructions334 of 348