2.4 EMC Installation Conditions2-132 Installation2.4 EMC Installation ConditionsThis section describes the recommended installation conditions that satisfy EMCguidelines for each model of the SGDV SERVOPACK. The conditions required forthe standard type (base-mounted) of SERVOPACK are described. Refer to this sec-tion for other SERVOPACK models such as the rack-mounted types as well.This section describes the EMC installation conditions satisfied in test conditionsprepared by Yaskawa. The actual EMC level may differ depending on the actual sys-tem’s configuration, wiring, and other conditions. However, because this product isbuilt-in, check that the following conditions are still met after being installed in theuser’s product.The applicable standards are EN55011 group 1 class A, EN61800-3, and EN61000-6-2.2.4.1 SGDV-01 (Analog Pulse Model) Single-phase 100 V• SGDV-F01A ( = R70, R90, 2R1, 2R8)Symbol Cable Name Specificationc I/O signal cable Shield cabled Safety signal cable Shield cablee Motor main circuit cable Shield cablef Encoder cable Shield cableg Main circuit cable Shield cablePower supply:Single-phase100 VACU, V, WL1, L2L1C, L2CCN2CN1Shield boxSERVOPACKPEPEEncoderServomotorBrake1345ClampNoisefilterBrake PowerSupplyClampClampClampCN82Surgeabsorber Two turnOne turnCoreCoreCoreCore CoreCoreTwo turnTwo turn ClampHostcontrollerSafety unitOne turn