6 Related Drive ParametersYASKAWA ELECTRIC TOBP C730600 89D YASKAWA AC Drive Option SI-EP3 Installation Manual 37F7-08(03EC)<11>Subnet Mask 4 Sets the static/fixed Subnet Mask.Parameter F7-08 sets the fourth most significant octet.Default: 0Min: 0Max: 255F7-09(03ED)<11>Gateway Address 1 Sets the static/fixed Gateway address.Parameter F7-09 sets the most significant octet.Default: 192Min: 0Max: 255F7-10(03EE)<11>Gateway Address 2 Sets the static/fixed Gateway address.Parameter F7-10 sets the second most significant octet.Default: 168Min: 0Max: 255F7-11(03EF)<11>Gateway Address 3 Sets the static/fixed Gateway address.Parameter F7-11 sets the third most significant octet.Default: 1Min: 0Max: 255F7-12(03F0)<11>Gateway Address 4 Sets the static/fixed Gateway address.Parameter F7-12 sets the fourth most significant octet.Default: 1Min: 0Max: 255F7-13(03F1)<11>Address Mode at StartupSelects how the option address is set.0: Static <10>2: DCPDefault: 2Range: 0, 2F7-14(03F2) Duplex Mode SelectionSelects duplex mode setting.0: Half/Half1: Auto/Auto2: Full/Full3: Half/Auto4: Half/Full5: Auto/Half6: Auto/Full7: Full/Half8: Full/AutoDefault: 1Range: 0 to 8F7-15(03F3)<12>Communication SpeedSelectionSets the communication speed.10: 10/10 Mbps100: 100/100 Mbps101: 10/100 Mbps102 100/10 MbpsDefault: 10Range: 10 to 102F7-23(03FB)<13>Dynamic Output AssemblyParameter 1 Sets configurable output 1.Default: 0HMin.: 0HMax.: FFFFHF7-24(03FC)<13>Dynamic Output AssemblyParameter 2 Sets configurable output 2.Default: 0HMin.: 0HMax.: FFFFHNo.(Hex.) Name Description Values