MAIN OVENNatural GasL.P. GasHeat Input 2.4kW (8189Btu/h) 2.4kW (172.4 g/h)Injector Marking 108 78Marking 69 78SECOND OVENNatural GasL. P. GasHeat Input 2.4kW (8189 Btu/h) 2.4kW (172.4g/h)Injector Marking 108 78Dual Control By-pass Fixed Internal Fixed InternalGENERALIgnition H. T. SparkSpark Gap 3-4mmGAS CATEGORY COUNTRIES OF DESTINATIONCAT. I2H GB, IECAT. I3 + GB, IEIMPORTANT - SAFETY REQUIREMENTSThis appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations CurrentEditions and the I.E.E. Wiring Regulations. For appliances installed in the Republic of Ireland please refer toNSAI - Domestic Gas Installation IS813 Current Editions. Detailed recommendations are contained in thefollowing British Standard Codes of Practice - BS.6172, BS.5440: Part 2 and B.S.6891. All British Standardsmust be 'Current Editions'.PROVISION FOR VENTILATIONThis appliance is not connected to a combustion products evacuation device. It shall be installed andconnected in accordance with the current installation regulations. Particular attention shall be given to therelevant requirements regarding ventilation.The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 CurrentEdition. All rooms require an openable window or equivalent and some rooms will require a permanent vent aswell. For room volumes up to 5m³ an air vent of 100cm² is required: for room volumes between 5m³ and10m³ an air vent of 50cm² is required. If the room has a door that opens directly to the outside, no air vent isrequired. For room volumes that exceed 11m³ no air vent is required. If there are other fuel burningappliances in the same room, BS.5440: Part 2 Current Edition should be consulted to determine the requisiteair vent requirements.Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, ormore effective ventilation, for example increasing the level of mechanical ventilation where present.41