3Once the hob has been installed, it isimportant to remove any protective materials,which were put on in the factory.Hob burners control knobsThe hob burners control knobs are situated on the hobright hand side. The symbols on the knobs mean that:there is no gas supplythere is maximum gas supplythere is minimum gas supplyLighting the burnersFor easier lighting, proceed before putting apan on the pan support.Models with semi-automatic ignitionTo light a burner, depress the relevant switchmarked with a small spark. Then, push in therelevant knob and turn it anticlockwise to "maximumposition" (ZGL 646 I) .Models with automatic ignitionPush in the relevant knob and turn it anticlockwiseto "maximum position". After lighting the flame,keep the knob pushed down for about 5 seconds.This will allow the "thermocouple" (Fig. 2, lett. D)to be heated and the safety device to be switchedoff, otherwise the gas supply would be interrupted(ZGL 646 IT - ZXL 636) .Then, check the flame is regular and adjust it asrequired.If you cannot light the flame even after severalattempts, check the "cap" (Fig. 1-2, lett. A) is inthe correct position.To put the flame out, turn the knob to the symbol z.• Always turn the flame down or put it out beforetaking the pans off the burner..ContentsThis appliance complies with the followingE.E.C. Directives:- 2006/95 (Low Voltage Directive);- 89/336 (Electromagnetical Compatibility Directive);- 93/68 (General Directives)and subsequent modifications.MANUFACTURER:ELECTROLUX HOME PRODUCTS ITALY S.p.A.Viale Bologna, 29847100 FORLÌ (Italy)For the User For the InstallerInstruction for the UserImportant Safety Information 2Instruction for the User 3Cleaning and Maintenance 5Technical Data 6Instruction for the Installer 6Electrical Connection 7Adaptation to different types of gas 8Building In 9Service and original spare parts 11Fig. 2 FO 0204A - Burner capB - Burner crownC - Ignition candleD - Thermocouple"""""•""""" Fig. 1In the absence of electricity, ignition can occurwithout the electrical device; in this case approachthe burner with a flame, push the relevant knobdown and turn it anti-clockwise until it reachesthe"maximum" position.When switching on the mains, after installation or apower cut, it is quite normal for the spark generatorto be activated automatically.