2EN - 6 - For the userThe CC Ease panel has a number of buttons to operate the ComfoAir and to enter the settings. These buttons areillustrated below.This button allows you to switch to the highest ventilation setting.- Press once Boost setting ON.- Press twice Boost setting OFF.This button allows you to switch between supply/exhaust.- Press once SUPPLY OFF (and EXHAUST ON).- Press twice EXHAUST OFF (and SUPPLY ON).- Press 3 times SUPPLY and EXHAUST both ON.With this button you can read or set the comfort temperature.- Press for less than 2 seconds READ.- Press for longer than 2 seconds SET.This button allows you to programme two settings.- Press for less than 2 seconds Programme ventilation setting (AUTO / MANUAL).- Press longer than 2 seconds Programme date and time.This button allows you to programme different settings:- In P menu Set values.- In main screen Enter ventilation setting (A, 1, 2, 3).2.3 Operating the CC Ease panelThe CC Ease panel is used for the following:• Reading and setting the day and time;• Reading and setting the comfort temperature;• Reading and setting the ventilation volume;• Activating the Boost setting;• Switching the supply and exhaust fan on/off;• Setting a personal ventilation programme;• Setting additional ventilation programmes/ op-tions in the P menus.A concise explanation of the above listing is given inthe paragraphs below.2.3.1 Setting the date and time1. Press " " longer than 2 seconds.- Wait until the day, e.g. “Sa”, starts blinking.2. Select the correct day using " " or " ".3. Press " ".- Wait until the hour, e.g. “ 12 ”, starts blinking.4. Select the correct hour using " " or" ".Day and timeActual ventilation settingAutomatic or manualventilationSignal to replaceinternal (I) filterSupply air and/orexhaust air OPEN orCLOSEDBypass activatedActual temperature,selection or setting