801910 - Zip Sparkling HydroTap - Installation Instructions - July 2014 - V1.00 Page 21 of 40Ventilation= =max 43314.0012.0012.00285.0012.005326.00CUT OUT DETAILSAA - KICKBOARD CUT-OUT1.Drill 4 pilot holes Ø12 in corners2.Finish cut-out using Jigsawand Keyhole or Wall Board sawB - CABINET FLOORCUT-OUT1.Drill two pilot holes Ø122.Finish cut-out using JigsawC - CABINET FLOORCUT-OUT1.Drill 4 pilot holes Ø12 in corners2.Finish cut-out using Jigsawand Keyhole or Wall Board sawATTENTION:Insure that: Cut outs 'A' and 'B' are on opposite side of cabinet.Cut out 'C' is straight behind'A'60.00B C12.0045.002842.4 The following instructions are critical if the vent kit, as supplied,is not fitted:If the kick board vent kit cannot be used then it is important to fit a standard HydroTap vent kit, which ensuresheat dissipation through natural convection via installed vents. For high use applications, where the cupboardspace temperature is near 35°C, or higher, an auxiliary ventilation kit must be fitted. (Contact your localservice centre for availability).Note: The vent kit has to be installed in a way that allows air to be drawn in from the bottom of the cupboardand expelled through the top of the cupboard. Therefore placement of the outlet vent should be towards thetop of the door (Option 1) or on the side of the cupboard (Option 2).Min 450mmFor positioning of cutout Cuse the template marked on the cardboard cartonSide outlet vent (Option 2)Door outletvent(Option 1)Front inlet ventCool Air INWarm Air OUTTypical airflowfor BCS with nokickboard venting