JA-63 „PROFI“ Alarm System - 11 - MGK554019.10 Reset enabledsequence: 2 8 xThe factory default reset (see 11) can be disabled. This wayno unauthorized future programming of the control panel will bepossible.options:2 8 1 reset enabled2 8 0 reset disabledWarning: if the Master or Service code is forgotten when thereset is disabled. The reset of the control panel will be possibleonly by the manufacturer.Factory default setting: reset enabled9.11 Arming control of a subsystemsequence: 2 9 0A wireless master control panel receives event signals(alarms, tampering, faults, low battery) from a JA-6x subsystemif enrolled – see 9.1 and 9.12. This will cause the same kind ofevent on the master control panel and J will be indicated as thesource of the event on the keypad.The master and slave control panels can be either armed anddisarmed as two independent systems or the slave system canfollow the arming and disarming of the master. If the mastershould rule arming of the slave subsystem, make the followingsettings:a. enroll a subsystem to the master‘s J position (see 9.1 and9.12),b. place the master panel into the programming mode (P isindicated),c. enter the enrolling mode in the sub-control panel (pressingkey 1 while in the programming mode)d. enter 290 on the master control panel – this way themaster will enroll to the slave sub-control panel as awireless controller (to the first free position of c1 to c8)e. turn both systems to standby mode and check that thesubsystem will arm after the master control panel is armed(in 2 seconds). Check the same for disarmingNotes:• Master control panel generates wireless commands Armand Disarm the same way as a remote control RC-40.The control panel transmits these commands only if it hasa subsystem enrolled in its position J.• The Arm command is generated when the master controlpanel is completely armed and also at the end of an alarmwhile the system remains completely armed (automaticalarm timeout). The Disarm command is generated whenthe master control panel is disarmed, when it is partlyarmed (home arming or one section arming if it is split)and also in the end of an alarm while the system isdisarmed (manual termination of the alarm).• The subsystem can also be operated by its othercontrollers (remote controls, keypads) if there are any. Forbetter understanding you can simply imagine, that themaster control panel is just another remote control.• Arming control of the subsystem by the master controlpanel can be disabled by erasing the corresponding cNposition in the sub-control panel. For example if themaster control panel was enrolled to position c3, scroll tothis position in the enrolling mode and holding key 2 willerase the master control panel as a controller.9.12 Enrollment of the control panel to a UC-2xx orto a master control panel sequence: 2 9 9The wireless control panel can send data to output modulesUC–216, UC–222 and UC-260. It can also work as a subsystemof another JA-6x.Enter the enrolling mode of the UC receiving device and thenenter 299 on the control panel. Note that the control panel mustbe in the programming mode. This enables the control panel togenerate the enrollment signal.If you want to enroll a subsystem to your control panel, enterthe enrolling mode on the MASTER control panel (see 9.1) andthen enter sequence 299 in the programming mode of the subcontrol panel.If the system is split, the sub control panel enrolls to thecommon shared section.9.13 No code requested for , , , (F1,F2, F3), F4, F8 & F9 sequence: 3 0 xIf this parameter is enabled, no code is requested for thefunctions listed above. When this parameter is disabled, thesefunctions (keys) can be used only when followed by a code(Master or User) – see the following table:„code“ = Master or UserFactory default setting: no code requestedNote: this feature is also selectable on the JA-60D wirelesskeypad and it is independent from the control panel setting.9.14 Partial (Home) arming with - non splitcontrol panel sequence: 3 1 xIn partial arming, the control panel reacts only to detectorsaddressed to section A (see 9.2 and 9.30) and it ignores thetriggering of detectors in section B or C (except smoke and gasdetectors). Partial arming can be disabled with this sequence.options:3 1 1 partial arming enabled3 1 0 partial arming disabledFactory default setting: partial arming enabled9.15 Hard wired siren alarm enabledsequence: 3 2 xThe SIR siren output is activated when any alarm is triggered(except silent Panic alarm). This siren indication can be disabledwith this parameter.options:3 2 1 siren enabled3 2 0 siren disabledFactory default setting: siren enabledfunction / setting 301 300arming „code“partial arming „code“door opening „code“memory reading F 4 F 4 „code“appliance control F80, F81 F8 “code” 0F8 “code” 1messagelistening F 9 F 9 „code“