JA-63 „PROFI“ Alarm System - 14 - MGK55401actions' tablea no splitting split system0 no action no action1 arm all arm all2 disarm disarm all3 partial arming arm A4 partial arming arm B5 disarm disarm A6 disarm disarm Bwhere:nn = number of the enrolled controller from 01 to 08 (c1 toc8)s = section: 1 = A, 2 = BNotes:• If the control panel is not split, this setting has no effect• For the JA-60F keypad this setting has no effect (its usercodes are determined by 62 nns setting)• The JA-60D keypad is effected the same way as RC-40remote controls (is addressed to a selected section)Example: to address controller number 5 to section A enter: 63 051Factory default setting: all wireless controllers are addressedto section A9.33 Automatic arming / disarming settingsequence: 64 nahhmmThe control panelcan automatically armand disarm for arequested period of aday. Up to teninstructions (time &action) can beprogrammed in theperiod of one day byentering: 64 nahhmmwhere:n = instruction number from 0 to 9a = action (see the actions' table)hh = hours (from 00 to 23)mm = minutes (from 00 to 59)Notes:• If any automatic action is selected, it will be preformedeveryday at the programmed time, following the internalcontrol panel clock.• The automatic arming and disarming can be overriddenmanually anytime (by a user code or a remote control)• If the control panel is in the requested arming mode beforethe action time, performance of the programmed action willnot change the armingExample: to program an automatic complete arming of thesystem at 21:15 everyday enter: 64 0 1 21 15Factory default setting: all instructions are set for no action9.34 New service code settingsequence: 5 nSC nSCThe Service Code can be used to enter the programmingmode. A new Service Code must be entered twice in a row toavoid an error. To change the code enter: 5 nSCnSCwhere:nSC = your new Service Code (four digits)Example: to change service code to 1276 enter: 5 1276 1276Factory default setting: service code is 60609.35 User Mode enteringSequence: 6 9 9 9This sequence is used to switch from the Programming Modeto the User Mode, where you can set zones´ bypass (see User’smanual). You can exit the User Mode by pressing the “N” button.The bypassed zones will remain active after the leaving the UserMode.9.36 Real time and date settingsequence: 4 hh mm dd MM YYThe control panel has a built in real time clock. All events arestored to the event memory including the time of the event. Theclock should be set after the installation is completed. TimeSetting: 4 hh mm dd MM YYwhere:hh = hours (24 hr. cycle)mm = minutesdd = dayMM = monthYY = yearExample: on Jun. 30 2007 at 17:15 enter: 4 17 15 30 06 07After the control panel is powered, its internal clock’s defaultsetting is: 00 00 01 01 00Note: detail control panel event history can be viewed with aconnected PC using Comlink software.10 System testingFor testing by installer, the control panel should be in theprogramming mode - "P" indicated on the keypad’s LED (F0Service Code). Testing can also be done by a user in the usermode (confirmed by “U”). The user mode is accessible with theMaster code. To open the user mode enter F 0 Master Codewhen the control panel is disarmed.No alarm can be triggered in programming or user modes andany triggering of a detector (wireless or wired) will result in a“beep” (press F to select a loud “beep” generated by a wiredsiren) and the display will briefly show which zone was triggered.Enrolled wireless controllers, sirens and other items’ signals willbe similarly indicated.• Some detectors (JA-60P, JA-60N, JA-60B etc.) have anextra testing mode, which is activated for 5 minutes after thedetector’s cover is attached (see manuals of the particulardetectors). If the detector is in testing mode, it will indicatetriggering locally with its LED, and it will also indicate thetriggering on the control panel keypad’s LED. Note that theJA-60P motion detector in normal mode (after 5 minutestesting mode) can not send next triggering information until5 minutes after the previous triggering was sent (this periodcan be shortened to 1 minute - see setting of the JA-60Pdetector).• Triggering of a detector wired to one of the L1 to L4inputs is indicated on the control panel keypad’s LED forabout 2 seconds after the triggering. So, if a detector ispermanently triggered for a longer period, it will not beindicated. If a double balanced input loop (2x 1k1) is used,then the control panel distinguishes triggering of thedetector from tampering.• The best way of testing is via a connected PC using theComlink software (see section 12). In the service eventswindow you will see a chronological record of all performedtests, including zone setting, quality of communication etc.11 Control panel factory default resetIf you forget the control panel codes or you have a controlpanel which is currently not under factory default settings,perform the following:• disconnect the AC power and back up battery in thecontrol panel and wait for 10 seconds.• connect (short) the RESET pins on the main board• leave the control panel cover open• reconnect back up battery and the AC power• within 1 minute disconnect the RESET jumper• reset is confirmed with a "P" (panel is in programmingmode)