JA-63 „PROFI“ Alarm System - 4 - MGK55401This product should be installed by professional installers. Themanufacturer assumes no liability for damages caused by incorrectinstallation or improper use of this system.1 Architecture of the control panelThe JA-63 "Profi" is a fully programmable control panel withbuilding block architecture. By programming, it can be split intotwo separately operated sections (with a shared section). It hasa built in power supply and there is ample space for a back upbattery (12V, 1.3Ah or 2.6Ah) in the control panel case.The JA-63K main board has 4 hard-wired inputs withprogrammable triggering (NC, balanced or double balanced) andprogrammable reactions.Model JA-63KR (equipped with the “R” radio communicatingmodule) has 16 wireless zones. Up to two JA-60 detectors can beenrolled into each zone (totally 32 as a maximum). In total model63KR has 20 zones (4 wired and 16 wireless). Up to 8 wirelesscontrollers (remote controls or wireless keypads), a JA-60Awireless siren and unlimited number of UC family wireless outputmodules can be enrolled as well. If more zones are required,another JA-6x control panel can be enrolled as a subsystem(Master & Slave architecture). The master control panel receivesinformation from the sub control panel and it can also arm anddisarm the subsystem panel.Telephone module “X” can communicate with a MonitoringStation, send two voice messages, send five SMS messagesvia SMS server (or dial a numeric Pager). It can alsocommunicate with a remote PC (using ComLink SW and a JA-60U modem).GSM dialer JA-60GSM sends SMS messages, calls topredefined telephone numbers and plays audible warning,communicates with 2 CMS, allows remote access from a phone’skeypad and can be set via web page.Operation and programming is possible via the JA-60Ekeypad. The control panel equipped with a radio module canalso be programmed and operated by a JA-60F wireless keypadand can also be operated by RC-40, RC-22 or RC-60 remotecontrols or by a JA-60D wireless keypad. Operation andprogramming is also possible via a PC using PC-60A interfaceand ComLink software.the internal layoutAvailable models of the JA-63 systemcontrol panel RmoduleXmoduleGSMmodule descriptionJA-63K no no no four zone hard wired control panelJA-63KR yes no no 16 zones wireless (up to 32 detectors) & 4 hard wired zonesJA-63KRX yes yes no 16 zones wireless (up to 32 detectors) & 4 hard wired zones & digital telephonecommunicator.JA-63KRG yes no yes 16 zones wireless (up to 32 detectors) & 4 hard wired zones & GSM dialer.Note: Radio module R can not be ”aftermarket” installed into 63K and 63KX models. Telephone communicator X module and GSM dialer JA-60GSM can be installedadditionally to a 63K or 63KR control panels.2 Control panel installation• The control panel should be easily accessible but not visible.There should be a power socket available and also atelephone line (if the system has an optional built in dialer).• Attach the control panel’s rear housing to the wall (seedrilling diagram on the last page of this manual).• Route all the cables to the control panel (power, input loops,telephone line etc.) before you tighten the case to thedesired location.Note: Only a qualified technician can provide the installation,telephone line connection and servicing. User is not allowed toopen the cover and/or make any modification.