10SetupSetting Up Your ManikinBefore SimMom is ready to run simulations, the manikin, birthing baby,and computer system must be setup correctly. This section coversthe following:– Connecting Belly Skin Audio Cable– Attaching Manikin Legs– Gown Features– Configuring System PC, Patient Monitor, and WebcamConnecting Belly Skin Audio CableTo connect the SimMom belly skin audio cable:1. Unhook the belly skin from the three attachment sites on eitherside of the pelvis and fold the skin over towards the feet.2. Remove the C-Section Belly skin shipped inside the pelvis andstore with your other SimMom accessories.3. Connect the black audio cable on the under side of the belly skinto the audio port located on the right side of the pelvis4. Reattach belly skin.Attaching Manikin LegsManikin legs allow full articulation and bend at the knee. They cansimulate maneuvers performed during various deliveries.To attach the manikin leg:1. Grip the thigh and gently push the hip clamp jaws onto the hipball on the pelvis.Note: If the jaws must be opened further to fit on the hip ball,turn the adjustment screw using the 8mm Allen key wrench.2. Tighten the adjustment screw using the 8mm Allen key wrenchuntil the desired tension on the hip is reached. Do not overtighten the adjustment screw because this may damage the jawsNote: Legs can be removed by loosening the adjustmentscrew and pulling them free of the hip ball.Gown FeaturesThe SimMom gown has two flaps that provide access to the abdomenduring birthing simulations. The gown also has holes through whichthe manikin’s wires can pass.Configuring SystemThe Instructor PC controls the simulator. It includes softwareprograms for creating and editing scenarios, as well as an applicationfor debriefing simulation sessions with video capture from a webcamera and the patient monitor.The Patient Monitor can be configured to replicate most patientmonitors. It also doubles as a display for other functions, such as12-lead ECG, X-ray images, and lab results to view the patient’s casehistory.The Web Camera records video and sound of the simulation for useduring the debriefing session.Setup Summary1. Start the Instructor PC– Connect the mouse and power supply to the computer andpower ON.– Make sure that the SimMom simulator icon is displayed on theInstructor PC desktop.2. Install the USB hub– Connect Power to the USB hub.– Connect USB hub to Instructor PC.3. Connect the Patient Monitor Cables– Put aside the software CD that comes with the monitor. DONOT INSTALL software CD.– Route the cables through the Patient Monitor stand and connectAbdominal AccessFlapAbdominal AccessFlapWire Exit