Adaptec ICP 5045BL manuals
ICP 5045BL
Table of contents
- Table Of Contents
- Table Of Contents
- Installing the Command Line Utility
- Installing on OpenServer and UnixWare
- Starting the Command Line Utility
- Table Of Contents
- Understanding the Command Line Utility
- Using Error Log Files
- arcconf create
- arcconf datascrub
- arcconf getconfig
- arcconf getstatus
- arcconf identify
- arcconf rescan
- arcconf setalarm
- arcconf setconfig
- arcconf snapshot
- HRCONF Commands
- hrconf create
- hrconf driverupdate
- hrconf getversion
- hrconf restore
- hrconf setconfig
ICP 5045BL
Table of contents
- Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- about this guide
- What You Need to Know Before You Begin
- Kit Contents and System Requirements
- Kit Contents
- About Your RAID Controller
- Standard RAID Controller Features
- Adding a Battery Backup Module
- About the ICP5805BL
- About the ICP5045BL
- About the ICP5085BL
- About the ICP5125BR
- About the ICP5165BR
- About the ICP9085LI
- About the ICP5085BR
- About the ICP9047MA
- About the ICP9087MA
- About the ICP9014RO
- About the ICP9024RO
- Getting Started
- Choosing a RAID Level
- Selecting Disk Drives
- Selecting Cables
- SATA Cables
- SCSI Cables
- Installing on an Existing Operating System
- Installing the Controller and Disk Drives
- Before You Begin
- Connecting Disk Drives to SAS RAID Controllers
- Connecting to a System Backplane
- Connecting Disk Drives to SATA RAID Controllers
- Connecting External Devices
- Creating a Bootable Array
- Setting the Boot Controller
- Creating an Array with ICP Storage Manager
- Making Your Array Bootable
- Installing the Driver and an Operating System
- Creating a Driver Disk
- Installing with Windows
- Installing with SUSE Linux
- Installing with OpenServer
- Installing with UnixWare
- Installing with FreeBSD
- Installing the Driver on an Existing Operating System
- Installing on Windows
- Installing on OpenServer
- Installing on UnixWare
- Installing on FreeBSD
- Managing Your Storage Space
- About ICP Storage Manager
- About the ICP RAID Configuration Utility
- Solving Problems
- Troubleshooting Checklist
- Failed Disk Drive Protected by a Hot Spare
- Multiple Failures in the Same Array
- Introduction to Serial Attached A SCSI
- Introduction to Serial Attached SCSI
- Terminology Used in This Chapter
- How Do SAS Devices Communicate
- What's a SAS Port
- How are Disk Drives Identified in SAS
- SAS Expander Connections
- How is SAS Different from Parallel SCSI
- Understanding RAID B
- Understanding RAID
- Understanding Drive Segments
- RAID 1 Arrays
- RAID 10 Arrays
- RAID 5 Arrays
- RAID 5EE Arrays
- RAID 50 Arrays
- RAID 6 Arrays
- Selecting the Best RAID Level
- Using the ICP RAID Configuration C Utility
- Table Of Contents
- Running the ICP RAID Configuration Utility
- Managing Existing Arrays
- Secure Erasing Disk Drives
- Modifying Your Controller's Configuration
- SAS-specific Controller Settings
- SCSI-specific Controller Settings
- Formatting and Verifying Disk Drives
- Viewing the Event Log
- Using the Array Configuration Utility for DOS
- Working in the ACU Using Menus
- Running the ACU Using Scripts
- About Record Mode
- Array Definition Block Keywords
- Channel Definition Block Keywords—SCSI only
- ACU Error Codes
- Sample Scripts
- Using the ICP Flash Utility
- System Requirements
- Creating the Firmware Floppy Disks
- Running the IFU from the Command Line
- Updating the Flash Using the IFU Command Line
- ICP Serial Controller LED and I2C Connector Reference
- ICP9047MA Activity LED and I2C Connector Specification
- ICP9087MA Activity LED and I2C Connector Specification
- ICP5805BL LED and I2C Connector Specification
- ICP5085BL LED and I2C Connector Specification
- ICP5125BR LED and I2C Connector Specification
- ICP5165BR LED and I2C Connector Specification
- ICP9085LI LED and I2C Connector Specification
- ICP5085BR LED and I2C Connector Specification
- Electrostatic Discharge (ESD)
- Table Of Contents
- DC Power Requirements
ICP 5045BL
Table of contents
- software license agreement
- Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- How This Guide is Organized
- What You Need to Know Before You Begin
- Part I: Getting Started
- Introduction to ICP Storage Manager
- Getting Started Checklist
- Growing Your Storage Space with ICP Storage Manager
- Continuing to Grow Your Storage Space
- System Requirements
- Installing ICP Storage Manager
- Installing on Windows
- Installing on Linux
- Installing on UnixWareor OpenServer
- Running ICP Storage Manager from the CD
- Building Your Storage Space
- Overview
- Starting and Logging In on the Local System
- Starting and Logging In
- Starting ICP Storage Manager on Remote Systems
- Logging into Remote Systems from the Local System
- Removing a Remote System
- Creating Logical Drives
- Custom Configuration (Advanced)
- Managing Your Storage Space
- Part II: Working in ICP Storage Manager
- Part II: Working in ICP Storage Manager
- Exploring ICP Storage Manager
- Working in ICP Storage Manager
- The Enterprise View
- The Physical Devices View
- The Logical Devices View
- Revealing More Device Information
- Checking System Status from the Main Window
- Logging Out of ICP Storage Manager
- Uninstalling From Solaris Systems
- Protecting Your Data
- Creating and Managing Hot Spares
- Assigning a Dedicated Hot Spare or Pool Hot Spare
- Removing or Deleting a Dedicated Hot Spare
- Creating a Snapshot
- Creating a Snapshot With Backup
- Creating a Snapshot Without Backup
- Modifying Your Direct Attached 6 Storage
- Modifying Your Direct Attached Storage
- Understanding Logical Drives
- Creating and Modifying Logical Drives
- Including Different-sized Disk Drives in a Logical Drive
- Creating a Logical Drive Using Available Segments
- Fine-tuning Logical Drives
- Changing the Stripe Size
- Changing the Initialize Priority
- Verifying and Fixing a Logical Drive
- Enabling/Disabling Background Consistency Check
- Extending a Partition on a Logical Drive
- Changing the RAID Level of a Logical Drive
- Creating a RAID Volume
- Scheduling Recurring or Resource- 7 Intensive Jobs
- Table Of Contents
- Scheduling a Task
- Opening the Task Manager
- Monitoring Tasks
- Modifying a Task
- Re-enabling the Task Manager
- Maintaining Physical Devices
- Viewing Component Properties
- Working with Failed or Failing Disk Drives
- Initializing Disk Drives
- Registering New Controllers
- Rescanning a Controller
- Testing and Silencing System and Enclosure Alarms
- Working with Enclosure Alarms
- Updating the Controller BIOS and Firmware
- Monitoring Status and Activity
- Monitoring Options
- What Do the Event Status Icons Mean
- Using Enclosure Icons to Monitor Enclosure Status
- Notifying Users by Event Log Message About Status and Activity
- Sending a Test Event
- Modifying a System's Information or Remove a System
- Disabling Logged Notifications
- Notifying Users by Email About Status and Activity
- Sending a Test Message
- Modifying a Recipient's Information or Removing a Recipient
- Disabling Email Notifications
- Notifying Users by SNMP Trap About Status and Activity
- Setting Up SNMP Notifications on Linux
- Changing an Operating System's Event Log Setting
- Updating and Customizing ICP 10 Storage Manager
- Updating and Customizing ICP Storage Manager
- Updating Adaptec Storage Manager
- Reorganizing the Enterprise View
- Setting the Standard Unit of Measure
- Adding and Removing Remote Systems in the Wizard
- Changing Auto-Discovery Settings
- Working with Display Groups
- Creating Display Groups
- Viewing Display Group Status
- Renaming a Display Group
- Solving Problems
- General Troubleshooting Tips
- Stopping the Creation of a New Logical Drive
- Failed Disk Drive Not Protected by a Hot Spare
- Multiple Disk Drive Failures in the Same Logical Drive
- Forcing a Logical Drive with Multiple Drive Failures Back Online
- Solving Notification Problems
- Understanding Error and Warning Messages
- Part III: Appendices
- windows installation
- Completing a Silent Installation
- Available Properties and Values
- Selecting the Best RAID Level B
- Selecting the Best RAID Level
- Comparing RAID Levels
- Non-redundant Logical Drives (RAID 0)
- RAID 1 Logical Drives
- RAID 10 Logical Drives
- RAID 5 Logical Drives
- RAID 5EE Logical Drives
- RAID 50 Logical Drives
- RAID 6 Logical Drives
- Quick Answers to Common Questions
- Set up my storage space
- Log out of ICP Storage Manager
- What's the difference between
- Controllers
- Logical drives
- The Task Manager
Related products
ICP 5085BLICP9047MAICP9024ROICP9087MAICP9014ROICP5085BRICP9085LI2255100-R - ICP Vortex ICP5805BL RAID ControllerRAID 50852251500-R - ICP Vortex ICP5165BR RAID ControllerAdaptec categories
Computer Hardware
Controller
Adapter
Software
Host Adapter
Storage
PCI Card
Network Card
Network Storage Server
Enclosure
manualsdatabase
Your AI-powered manual search engine