RF Sensor Programming Steps©2013 2GIG Technologies Inc. All Rights Reserved. 33Select RF sensor (#) chime (0-5)DEFAULT: Disabled (0)Each RF sensor can be set to sound a “ding‐dong”chime and/or sound its voice descriptor when thesensor is triggered. This step determines the initialsetting for the sensor. The end user can change thechime setting for sensors using Chime Setup in theUser Toolbox.• The default (0) disables the chime for this RFsensor.• If a chime and/or voice is required for this RFsensor, choose one of the other chimeoptions:RF Sensor Chime(0) disabled (7) ding‐ding with voice(1) voice only (8) ding‐dong #3(2) ding‐dong with voice #1 (9) ding‐dong with voice #3(3) ding‐dong #2 (10) chime #1(4) ding‐dong with voice #2 (11) chime #1 with voice #1(5) ding‐dong #1 (12) chime #2(6) ding‐ding (13) chime #2 with voice #2WIRED SENSORPROGRAMMINGWired Sensor Programming OutlineThe Control Panel can be programmed with up to 2wired sensors. The wired sensors are hardwiredcontact loops connected to the loop inputterminals on the Control Panel’s terminal strip. Tosee where the 2 hardwired sensors can be wiredinto the Terminal Block, see the "Terminal BlockWiring Diagram" on page 15.CAUTION: Wired Sensors CANNOT be usedfor a CO or Fire Sensor Loop!To program the wired sensors into the ControlPanel, do the following:• Select the sensor number (between 1 or 2)• Select the wired sensor type• Set the equipment code• Program the loop type:• Open• Closed• End‐of‐line resistor• Select the other options for the sensor (seethe diagram on the next page)IMPORTANT: Wired sensors 1 and 2 report to theControl Panel as sensors 49 and 50.Wired Sensor Reporting CodesWired Sensor #1 = Reports as Sensor #49Wired Sensor #2 = Reports as Sensor #50See the diagram on the next page for the stepsrequired to program wired sensors into the ControlPanel. The options that can be set for each wiredsensor are:• Wired Sensor Number — Sensor #1 or 2• Wired Sensor Type — Exit/entry, perimeter,interior, etc.• Wired Sensor Equipment Type — Certainsensor types will require the installer to enteran equipment type (but not all)• Wired Sensor Equipment Code — 4‐digitequipment code that matches installed sensor• Wired Sensor Equipment Age — New install orexisting sensor• Wired Sensor Normal State — normally open,closed, or end‐of‐line resistor loop• Wired Sensor Dialer Delay — Delayed orinstant communicator reports for the sensor(delay time is set by dialer abort window)• Wired Sensor Voice Descriptor — Nameassigned to the sensor• Wired Sensor Reports — Communicatorreports or no communicator reports for thesensor• Wired Sensor Chime — Select voiceannouncement and chime options for thesensor