90 Installation example of drive module with IP20 shrouds (option +B051)Required partsRequired tools• Set of screw drivers (Torx and Pozidriv)• Set of metric magnetic-end hexagon sockets• Torque wrench• Step drill bit for drilling the holes in the clear plastic shroud for input power cables.Overall flowchart of the installation processDrive module standard parts• Drive module• Fastening bracket• Pedestal guide plate• Telescopic extraction and insertion ramp• Fastening screws and insulators in a plastic bag• External control unitRittal partsRittal part code Qty(pcs)DescriptionTS 8606.500 1 Enclosure without mounting plate, bottom plates and side panels.TS 8612.160 5 Punched section with mounting flange, outer mounting level for 600 mmhorizontalTS 4396.500 Support railsSK 3243.200 4 Air filter 323 mm × 323 mm. Remove the filter mats.Customer-made parts (not ABB or Rittal products)Air baffles 2 See section Preventing the recirculation of hot air on page 45 and section Airbaffles for the drive module with option +B051 on page 132.Step Task For instructions, see1 Install the Rittal parts, drive bottom guide plateand loose drive options in the drive modulecubicle.Installing the drive module into a cabinet onpage 91 and installation drawings on page171.2 Install the auxiliary components (such asmounting plates, air baffles, switches, busbarsetc.).The component manufacturer’s instructionsPreventing the recirculation of hot air on page45.Attach the drive module to the cabinet Step-by-step drawings for an installationexample of drive module with options +B051and +E208 in Rittal TS 8 600 mm wide cabineton page 171.Connecting the power cables and installing theshrouds on page 913 Connect the power cables and clear plasticshrouds to the drive module.6 Connect the control cables. Connecting the control cables, page 807 Install the remaining parts, for example, cabinetdoors, side plates, etc.The component manufacturer’s instructions.Installing the roof and door on page 93