As the public IP address of ARM600 is case dependent, it is notpossible to define an example. If ARM600 is located in DMZ,the eth0 IP address can be a private IP address. In that case thespecific ports are forwarded to ARM600 by border router.Table 11:Eth0 settingsParameter ValueDevice eth0BOOTPROTO noneIPADDR NETMASK1) PREFIX1) GATEWAY DNS1, DNS2 Set the DNS servers, if needed.DEFROUTE YesIPV6_DEFROUTE Yes1) Set either the netmask or the prefixThe default route is usually set pointing the router in ARM600’seth0 subnet. The Arctic devices usually connect from unknown(dynamic) IP addresses via the eth0 interface, which is bydefault the WAN interface in ARM600.9. Click Save.10. Click Restart interface eth0.The IP address of the eth0 interface used for the currentconnection to ARM600 has now been changed. After thechanges to the eth0 IP address have been applied the browserwill not be able to connect to ARM600 using the address https://10.10.10.10:10000.11. Switch the Ethernet cable from ARM600’s WAN interface to the LAN interface.• In the standard edition, switch the Ethernet cable to the Gb2 interface.• In the Enterprise edition, switch the Ethernet cable to port 2.If the eth1 interface has been configured according to this example,use the address https://192.168.0.1:10000 to access ARM600 via itseth1 (LAN) port. Remember to change the PC’s IP addressaccordingly. For example, use the IP address 192.168.0.2 in the PCwith netmask 255.255.255.0.Section 6 1MRS758861 ANetwork configuration28 ARM600User Manual
PreviousNext |