Control Port Operation HDSL2 for General Distribution Installation and Maintenance Practice22 61223HDSL2L2-5BProvisioningThe Provisioning menu (Figure 16) displays current settings. To change a particular optionsetting (for example, “1” for DSX-1 Line Build Out) select the appropriate number, press E NTER,and the new menu will appear with a list of the available settings. To return to this screenand/or the Main Menu, press E SC. To re-deploy this unit, press D which will restore the factorydefault settings to those shown in Table 6 on page 11.Figure 16. Provisioning ScreenNOTEDSX-1 Line Build Out is set to 0-133 feet. This option is set toEXTERNAL if using a Kentrox shelf. Otherwise, the LBO optionshould be set to zero (0).NOTEShelf Alarm option is on the DDM+ and 3192 modules only.Total Access 3000 H2TU-C Provisioning MenuTwo screens comprise the provisioning menu for the Total Access 3000 H2TU-C. Figure 17illustrates the first page of the menu.Press the N (and E NTER) to move forward to the next screen. Figure 18 shows the remainder ofthe Provisioning menu.To return to the previous screen, press P.To return to the Main Menu, press E SC.Circuit ID:HNTSVLALHDSL2 03/01/05 09:29:45Press ESC to return to previous menuProvisioning1. DSX-1 Line Buildout = 0-133 feet2. DSX-1/DS1 Line Code = B8ZS3. DSX-1/DS1 Framing = ESF4. Forced Frame Conversion = Disabled5. Smartjack Loopback = Enabled6. Loopback Timeout = 120 Minutes7. Latching Loopback Mode = T1 (Disabled)8. DS1 TX Level = 0 dB9. Span Power = Enabled10. Customer Loss Indicator = AIS / CI11. PRM Setting = AUTO12. Loop Atten Alarm Thres = 30 dB13. SNR Margin Alarm Thres = 04 dB14. Remote Provisioning = Enabled15. Shelf Alarm = EnabledD. Restore Factory DefaultsSelection: