Absolute Process Instruments APD 1200 Quick Start Manual
Thermocouple Input Alarm Trips, Isolated, Factory Configured APD 1200, APD 1220Input: 2 or 3 Wire ThermocoupleOutput: Two 8 Amp SPDT RelaysO Factory Set T/C Type and Temperature RangeO Adjustable Trip and Reset PotentiometersO Input LoopTracker®and Alarm Status LEDsO Full 1200 V IsolationO Alarm Test, Optional Latching Reset ButtonO Automatic Cold Junction CompensationQ Process Limit AlarmQ Monitor, Heaters, Refrigerators, OvensQ Process Signal Over or Under AlarmsApplicationsThermocouple Input, Factory ConfiguredSpecify T/C type: J, K, T, E, R, S, N, B, C, D, G, M, PSpecify temperature range in °F or °CFull ANSI temperature rangesLinearization: 41-55 segment or up to 14th order polynomial100°F (55°C) is the recommended minimum spanConsult factory if a smaller span is requiredCold Junction CompensationAutomatic for specified thermocoupleT/C Burnout ProtectionUpscale burnout protection standardB option: Downscale burnout protectionNB option: NoneT/C CurrentLess than 1.0 μA, including burnout senseIsolationPower to input isolation: 1200 VCommon mode protection: 600 VACp or 600 VDCLoopTrackerVariable brightness LED indicates input level and statusAPD 1200 Relay OutputSingle setpoint dual DPST contact sets, field configurable2 Form A (NO) and 2 Form B (NC) contact sets (8 terminals)May be field wired for Form C operationOne set point, 12 turn potentiometer, 0-100% of spanOne reset point, 12 turn potentiometer, 0-100% of spanFactory configured alarmStandard: HI alarm, non-latching, normal actingAPD 1220 Relay Output2 independent setpoint DPST contact sets, field configurableSP 1: Form A (NO) and Form B (NC) contacts (4 terminals)SP 2: Form A (NO) and Form B (NC) contacts (4 terminals)May be field wired for Form C operationTwo set points, two 12 turn potentiometers, 0-100% spanTwo reset points, two 12 turn potentiometers, 0-100% spanFactory configured alarmStandard: HI/LO alarm, non-latching, normal actingOptions: LO/LO, HI/HI, LO/HI alarms, band alarms,latching, reverse actingRelay Contact Ratings8 A max @ 240 VACresistive load.External contactprotection such asan RC snubber isrecommended forinductive loads.Response Time300 milliseconds typicalOutput Test/Reset ButtonFront button or external contact closure toggles relays toopposite state when pressed.Resets relay if latching relay option is orderedAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than 0.04% of span per °CSwitching Current (A)Switching Voltage (V)0 3 5 10 30 50 100 300 50085310.50.30.1AC inductive load(cos f = 0.4) AC resistiveloadDC inductive load(L/R = 7 ms)DC resistiveload© 07-20api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502AABSOLUTEBSOLUTE PPROCESSROCESS IINSTRUMENTSNSTRUMENTSDescriptionThe APD 1200 series accepts a thermocouple input and pro-vide a visual alarm indication and alarm relay contact outputs.The input type, range, and alarm types are factory configured.The input can be factory configured for most thermocoupletypes.Front-accessible potentiometers are used to adjust alarm tripand reset point(s).LoopTracker and Alarm Status LEDsAPI exclusive features include a LoopTracker LED that variesin intensity with changes in the process input signal.A red/green bicolor alarm status LED(s) visually indicatealarm status. These LED(s) provide a quick visual picture ofyour process at all times.Output Test / UnlatchAPI's exclusive Output Test button can be used to verify thealarm and system operation and also provides the additionalfunction of unlatching the alarm when the latching option hasbeen ordered.The output test button greatly aids in saving time during initialstartup and/or troubleshooting.Dimensions0.89" W x 4.62" H x 4.81" D (22.5 x 117 x 122 mm)Height includes connectorsHousing and ConnectorsIP 40, requires installation in panel or enclosureFor use in Pollution Degree 2 EnvironmentMount vertically to a 35 mm DIN railFour 4-terminal removable connectors, 14 AWG max wire sizePower85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximumD versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximumQuick Link: api-usa.com/1000Input: Most Thermocouple TypesOutput: Two 8 Amp DPST Relays Quick Link: api-usa.com/1200Pb LeadFreeModel Input Standard Alarm Configuration PowerAPD 1200 Factory ranged, specifyT/C type,°F or °C range,Options if required.Upscale burnout standardHI alarm, single setpoint, dual DPST relaysnon-latching, normal acting, upscale burnout85-265 VAC or 60-300 VDCAPD 1200 D 9-30 VDC or 10-32 VACAPD 1220 HI/LO alarms, 2 setpoints, 2 DPST relaysnon-latching, normal acting, upscale burnout85-265 VAC or 60-300 VDCAPD 1220 D 9-30 VDC or 10-32 VACOptions—add to end of model numberB Downscale burnout protectionNB No burnout, last valid inputL APD 1200 with LO trip. Alarm trips on decreasing signal.HH APD 1220 with HI/HI trip. Alarms trip at their respectivetrip points on increasing signal.LL APD 1220 with LO/LO trip. Alarms trip at their respec-tive trip points on decreasing signal.LH APD 1220 with LO/HI trip. Alarm 1 trips on decreasingsignal. Alarm 2 trips on increasing signal.BA APD 1220 with band alarm. Alarm trips if signal is out-side LO and HI trip points.IBA APD 1220 with inverse band alarm. Alarms trip if signalis between LO and HI trip points.HT Latching alarm with push button resetHP Latching alarm with power-off reset. Module powermust be turned off to reset alarmsR Reverse-acting alarms. Relay coils energized in an alarmcondition. No alarm condition with module power off.U Conformal coating for moisture resistanceAccessory—order as separate line itemAPI BP4 Spare removable 4 terminal plug, blackFree FactoryI/O Setup!H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAApplications Linkapi-usa.com/appsUniversal PowerAlarm Status LEDInput LoopTracker LEDAlarm Test FunctionAdjustable DeadbandTwo 8 Amp SPDTAlarm RelaysCustom Input RangesRemovable PlugsAdjustable Setpoint1 2 3 45 6 7 89 10 11 1213 14 15 16 See WiringDiagrams onNext Page1 2 3 45 6 7 89 10 11 1213 14 15 16 |
Related manuals for Absolute Process Instruments APD 1200
Absolute Process Instruments APD 1400 Quick Start Manual
Absolute Process Instruments APD 1431 Quick Start Manual
Absolute Process Instruments API 1080 G Quick Start Manual
Absolute Process Instruments API 1005 G Quick Start Manual
Absolute Process Instruments API 1040 G Series Quick Start Manual
Absolute Process Instruments API 1000 G Manual
Absolute Process Instruments Cecomp F16ADA Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine