Absolute Process Instruments API 1080 G Quick Start Manual
DC Input Alarm Trips, Isolated, Field Configurable API 1080 G, API 1090 GInput: 0-50 mV to ±10 VDC, 0-1 mA to 4-20 mADCOutput: One 8 Amp DPDT Relay or Two 8 Amp SPDT RelaysO One Minute Setup for 24 Input RangesO Switch Selectable Relay ConfigurationO Adjustable Setpoint and DeadbandO Input LoopTracker®and Alarm Status LEDsO Hot Swappable Plug In DesignO Alarm Test / Reset ButtonO Built-In Loop Power Supply for Sink/Source InputQ Process Limit Backup AlarmQ Tank Level AlarmQ Process Signal Over, Under, Out-of-Range AlarmApplicationsOption—add to end of model numberU Conformal coating for moisture resistanceAccessories—order as separate line itemAPI 011 11-pin socket, DIN rail or surface mountAPI 011 FS 11-pin finger safe socket, DIN rail or surface mountAPI CLP1 Module hold-down spring for high vibration ormobile applicationsModel Input Output PowerAPI 1080 G Field configurablespecify range if factory is to setswitchesSingle setpoint field configurableDPDT relay configuration,specify configuration for factory setup115 VACAPI 1080 G A230 230 VACAPI 1080 G P 85-265 VAC or 60-300 VDCAPI 1080 G D 9-30 VDCAPI 1090 G Field configurablespecify range if factory is to setswitches2 setpoint field configurable2 SPDT relays,specify configuration for factory setup115 VACAPI 1090 G A230 230 VACAPI 1090 G P 85-265 VAC or 60-300 VDCAPI 1090 G D 9-30 VDCDescriptionThe API 1080 G and API 1090 G accept a DC voltage or cur-rent input and provide visual alarm indication and alarm relaycontact outputs. Voltage and current input ranges can befield-configured via external rotary and slide switches. Offsetranges such as 1-5 VDC and 4-20 mADC are also included.Heavy-duty relay contacts allow the module to directly controlhigh capacity loads. Top-accessible potentiometers are usedto adjust the alarm setpoint from 0 to 100% and the deadbandfrom 1 to 100%.The API 1080 G provides a single setpoint adjustment of thetwo DPST relay contacts. The alarm output can be field con-figured for HI or LO operation, latching or non-latching, andnormal or reverse acting. The deadband and alarm setpointare adjustable.The API 1090 G provides two setpoint adjustments of the twoSPDT relay contacts. The alarm outputs can be configured inthe field for HI/HI, LO/LO, HI/LO or LO/HI operation, latchingor non-latching, and normal or reverse acting. Deadband andalarm setpoints are independently adjustable for each alarm.Sink/Source Input and Loop SupplyFor maximum versatility, a current input can be selectivelywired for sinking or sourcing. This allows the API 1080 G andAPI 1090 G to work with powered or unpowered mA inputs.An unregulated 18 VDC loop excitation supply can be usedto power passive input devices eliminating the need for anadditional DC loop supply.LoopTracker and Alarm Status LEDsAPI exclusive features include a LoopTracker LED that variesin intensity with changes in the process input signal. A red/green bi-color alarm status LED (two on the API 1090) visuallyindicate alarm status. These LEDs provide a quick visual statusof your process at all times.Output Test / UnlatchAPI’s exclusive functional test button can be used to verify thealarm and system operation. The output test button greatlyaids in saving time during initial startup and/or troubleshooting.The HT latching option provides the additional function ofunlatching the alarm when the reset button is pressed. Thealarm will reset if the alarm condition not longer exists.DC Input Ranges24 switch selectable ranges. See table on other side.Voltage: 0-50 mVDC to 0-10 VDCBipolar voltage: ±5 VDC or ±10 VDCCurrent: 0-1 mADC to 0-20 mADC, 4-20 mADCInput Impedance, Burden, ProtectionVoltage: 250 kΩ minimumCurrent: 50 Ω typical (1 VDC burden at 20 mA)Common mode protection: 750 VACp or 750 VDCInput Loop Power Supply18 VDC unregulated, 25 mADC, <1.5 Vp-p rippleMay be selectively wired for sinking or sourcing mA inputLoopTrackerVariable brightness LED indicates input loop level and statusAPI 1080 G Relay OutputTwo SPDT form C contact sets operating in unison as oneDPDT contact setOne 12 turn setpoint potentiometer, 0-100% of spanOne 12 turn deadband potentiometer, 1-100% of spanField configurable alarm type, action, and latchingAPI 1090 G Relay OutputTwo independent SPDT form C contact setsTwo 12 turn setpoint potentiometers, 0-100% of spanTwo 12 turn deadband potentiometers, 1-100% of spanField configurable alarm type, action, and latchingRelay Contact Rating8 A @ 240 VAC resistive load or 30 VDC resistive load max.Caution: Do not exceed socket voltage ratingUse an RC snubber for inductive loadsOutput Test/Reset ButtonToggles relay to opposite state when pressedResets latching relay if latching relay mode is selectedResponse Time70 milliseconds typicalAmbient Temperature Range and Stability–10°C to +60°C operating ambient,Better than 0.02% of span per °C stabilityHousing and SocketsIP 40, requires installation in panel or enclosureAPI 011 or API 011 FS socketSocket mounts to 35 mm DIN rail or can be surface mountedPowerStandard: 115 VAC ±10%, 50/60 Hz, 2.5 W max.P option: 85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W typ.A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.D option: 9-30 VDC, 2.5 W typicalMinuteSetup!1 Free FactoryI/O Setup!Quick Linkapi-usa.com/1080Variable Brightness Input LEDBi-Color Relay LEDDeadband AdjustmentSetpoint AdjustmentOutput Test ButtonAPI 1080 G2.38"1.75"2.75"Switching Current (A)Switching Voltage (V)0 3 5 10 30 50 100 300 50085310.50.30.1AC inductive load(cos f = 0.4) AC resistiveloadDC inductive load(L/R = 7 ms)DC resistiveloadRelay Contact Ratings2.75"API 1090 G2.38"1.75"Variable Brightness Input LEDBi-Color Relay 2 LEDBi-Color Relay 1 LEDDeadband 2 AdjustmentDeadband 1 AdjustmentSetpoint 2 AdjustmentSetpoint 1 AdjustmentOutput Test ButtonQuick Linkapi-usa.com/1090H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAHot SwappablePlug-In DesignAPI 011300 V RatingAPI 011 FS300 V Rating API CLP1www.mod-tronic.com | sales@mod-tronic.com | 1-800-794-5883 |
Related manuals for Absolute Process Instruments API 1080 G
Absolute Process Instruments API 1005 G Quick Start Manual
Absolute Process Instruments API 1040 G Series Quick Start Manual
Absolute Process Instruments APD 1431 Quick Start Manual
Absolute Process Instruments APD 1200 Quick Start Manual
Absolute Process Instruments APD 1400 Quick Start Manual
Absolute Process Instruments API 1000 G Manual
Absolute Process Instruments Cecomp F16ADA Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine