Absolute Process Instruments APD 1400 Quick Start Manual
RTD Input Alarm Trips, Factory Ranged, Isolated APD 1400, APD 1420Input: 2 or 3 Wire RTDOutput: Two 8 Amp SPDT RelaysO Factory Set Input RangeO Removable Plugs for Faster InstallationO Input LoopTracker®and Alarm Status LEDsO Full 1200 V IsolationO Alarm Test, Optional Reset ButtonO RTD Leadwire CompensationQ Process Limit AlarmQ Monitor, Heaters, Refrigerators, OvensQ Process Signal Over or Under AlarmsApplicationsTemperature InputFactory configured, please specify the followingResistance at 0°C, curve, temperature rangeRTD types: 10 Ω to 2000 Ω RTDs including100 Ω 0.00385 DIN, 100 Ω 0.003916,100 Ω 0.00392, 10 Ω Cu,1000 Ω Ni-Fe, 120 Ω NiTemperature range: °F or °C100°F (55°C) min. span or consult fac-toryRTD Typical Excitation Current10 Ω: 10 mA 100 Ω: 2 mA1000 Ω: 0.5 mA 2000 Ω: 0.2 mALeadwire Compensation< ±0.05% of span per 1 Ω change in leadwire resistanceIsolationPower to input isolation: 1200 VCommon mode protection: 600 VACp or 600 VDCLoopTrackerVariable brightness LED indicates input level and statusAPD 1400 Relay OutputDual SPDT Form C contact sets operating in unison1 setpoint adjustment, 1 deadband adjustmentStandard: HI alarm, non-latching, normal actingOptions: LO alarm, latching, reverse actingAPD 1420 Relay Output2 independent SPDT Form C contact sets2 setpoint adjustments, 2 deadband adjustmentsStandard: HI/LO alarm, non-latching, normal actingOptions: LO/LO, HI/HI, LO/HI alarms, latching, reverse actingRelay Contact Ratings8 A max @ 240 VAC resistive loadExternal contact protection such as an RC snubber is recom-mended for inductive loadsSetpoint12 turn potentiometer adjustable from 0 to 100% of spanDeadband12 turn potentiometer adjustable from 1 to 100% of spanResponse Time70 milliseconds typicalOutput Test/Reset ButtonFront button or external contact closure toggles relays toopposite state when pressed.Resets relay if latching relay option is orderedAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than 0.04% of span per °CSwitching Current (A)Switching Voltage (V)0 3 5 10 30 50 100 300 50085310.50.30.1AC inductive load(cos f = 0.4) AC resistiveloadDC inductive load(L/R = 7 ms)DC resistiveloadAlarm Options—add to end of model numberL APD 1400 with LO trip. Alarm trips on decreasing signal.HH APD 1420 with HI/HI trip. Alarms trip at their respectivetrip points on increasing signal.LL APD 1420 with LO/LO trip. Alarms trip at their respec-tive trip points on decreasing signal.LH APD 1420 with LO/HI trip. Alarm 1 trips on decreasingsignal. Alarm 2 trips on increasing signal.HT Latching alarm with push button resetHP Latching alarm with power-off reset. Module powermust be turned off to reset alarmsR Reverse-acting alarms. Relay coils energized in an alarmcondition. No alarm condition with module power off.U Conformal coating for moisture resistanceAccessory—order as separate line itemAPI BP4 Spare removable 4 terminal plug, black© 08-18api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502ABSOLUTE PROCESS INSTRUMENTSModel Input Standard Alarm Configuration PowerAPD 1400 Factory ranged, specify:Sensor typeCalibration curveTemperature range in°F or °CSingle setpoint dual SPDT relaysHI alarm, non-latching, normal acting85-265 VAC or 60-300 VDCAPD 1400 D 9-30 VDC or 10-32 VACAPD 1420 2 setpoints, 2 SPDT relaysHI/LO alarms, non-latching, normal acting85-265 VAC or 60-300 VDCAPD 1420 D 9-30 VDC or 10-32 VACDescriptionThe APD 1400 and 1420 accept an RTD temperature inputand provide a visual alarm indication and alarm relay contactoutputs.The input type, range, and alarm types are factory configured.The input can be configured for most 10 Ω to 2000 Ω RTDs.Front-accessible potentiometers are used to adjust alarmsetpoint and deadband.LoopTracker and Alarm Status LEDsAPI exclusive features include a LoopTracker LED that variesin intensity with changes in the process input signal.A red/green bi-color alarm status LED (two on the APD 1420)visually indicate alarm status.These LEDs provide a quick visual picture of your processat all times.Output Test / UnlatchAPI's exclusive Output Test button can be used to verify thealarm and system operation and also provides the additionalfunction of unlatching the alarm when the latching option hasbeen ordered. This feature can be remotely operated.The output test button greatly aids in saving time during initialstartup and/or troubleshooting.Dimensions0.89" W x 4.62" H x 4.81" D(22.5 x 117 x 122 mm)Height includes connectorsHousing and ConnectorsIP 40, requires installation in panel or enclosureFor use in Pollution Degree 2 EnvironmentMount vertically to a 35 mm DIN railFour 4-terminal removable connectors, 14 AWG max wire sizePower85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximumD versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximumQuick Link: api-usa.com/1000Input: 0-50 mV to ±10 VDC, 0-1 mA to 4-20 mADCOutput: Two 8 Amp DPST Relays1 2 3 45 6 7 89 10 11 1213 14 15 16 See WiringDiagrams onNext Page1 2 3 45 6 7 89 10 11 1213 14 15 16Universal PowerAlarm Status LEDInput LoopTracker LEDAlarm Test FunctionAdjustable DeadbandTwo 8 Amp SPDTAlarm RelaysCustom Input RangesRemovable PlugsAdjustable SetpointFile E14596885-265 VAC, 60-300 VDCmodel onlyFree FactoryI/O Setup!H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAQuick Link: api-usa.com/1400Applications Linkapi-usa.com/apps |
Related manuals for Absolute Process Instruments APD 1400
Absolute Process Instruments APD 1200 Quick Start Manual
Absolute Process Instruments APD 1431 Quick Start Manual
Absolute Process Instruments API 1080 G Quick Start Manual
Absolute Process Instruments API 1005 G Quick Start Manual
Absolute Process Instruments API 1040 G Series Quick Start Manual
Absolute Process Instruments API 1000 G Manual
Absolute Process Instruments Cecomp F16ADA Instructions Manual
manualsdatabase
Your AI-powered manual search engine