Absolute Process Instruments API 1000 G Manual
Input: 0-100 mV to 300 VDC, 0-1 mA to 0-5 ADC, 4-20 mADCOutput: One 8 Amp DPDT Relay or Two 8 Amp SPDT RelaysO Field Adjustable SetpointsO Plug-In Design for Fast InstallationO Input LoopTracker®and Alarm Status LEDsO Alarm Test, Optional Reset ButtonO Sinking mA InputQ Process Limit Backup AlarmQ Tank Level AlarmQ Process Signal Over, Under, Out-of-Range AlarmModel Input Standard Alarm Configuration PowerAPI 1000 G Factory ranged, specifymV, V, or mA rangeOrder 5A shunt option for 0-900mADC to 0-5 ADC inputsSingle setpoint one DPDT relayHI alarm, non-latching, normal acting115 VACAPI 1000 G A230 230 VACAPI 1000 G P 85-265 VAC or 60-300 VDCAPI 1000 G D 9-30 VDCAPI 1020 G Factory ranged, specifymV, V, or mA rangeOrder 5A shunt option for 0-900mADC to 0-5 ADC inputs2 setpoints, 2 SPDT relaysHI/LO alarms, non-latching, normal acting115 VACAPI 1020 G A230 230 VACAPI 1020 G P 85-265 VAC or 60-300 VDCAPI 1020 G D 9-30 VDCDC Input RangeFactory configured, please specify input type and rangeSystem voltages should not exceed socket voltage ratingVoltage: 0-100 mVDC to 0-300 VDCCurrent: 0-1 mADC to 0-900 mADC sinking5A option: 0-900 mADC to 0-5 ADCInput Impedance and BurdenVoltage: 250 kΩ minimumCurrent: 50 Ω typicalVoltage burden: 1.25 VDC at 20 mA current inputIsolation and Input Protection750 VACp or 750 VDC common mode protectionInput isolated from power supplyLoopTrackerVariable brightness LED indicates input loop level and statusAPI 1000 G Relay OutputTwo SPDT form C contact sets operating in unison as oneDPDT contact setOne setpoint, 12 turn potentiometer, 0-100% of spanFactory configured alarm typeStandard: HI alarm, non-latching, normal actingOptions: LO alarm, latching, reverse actingAPI 1020 G Relay OutputTwo independent SPDT form C contact setsTwo setpoints, two 12 turn potentiometers, 0-100% of spanFactory configured alarm actionInternal jumpers for HI/LO, LO/LO, HI/HI, LO/HIStandard: HI/LO alarm, non-latching, normal actingOptions: LO/LO, HI/HI, LO/HI alarms, latching, reverse actingRelay Contact Rating8 A @ 240 VAC resistive load or 30 VDC resistive load5 A @ 240 VAC inductive load (cos f = 0.4)3.5 A @ 30 VDC inductive load (L/R = 7ms)See graph on other side for relay load ratingsCaution: Do not exceed socket voltage ratingUse an RC snubber for inductive loadsDeadbandAlarm trip/reset window is symmetrical about the setpointAPI 1000 G 1.0 to 100% of span, 12 turn potentiometer.API 1020 G Fixed at 1% of span, standardAPI 1020 G A Adjustable deadbands, 1.0 to 100% of span,1 turn potentiometer for each setpointOutput Test/Reset ButtonToggles relay(s) to opposite state when pressedResets latching relay with HT option, available on 1000 G onlyResponse Time70 milliseconds typicalAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than 0.02% of span per °C stabilityHousing and SocketsIP 40, requires installation in panel or enclosureAPI 011 or API 011 FS socketSocket mounts to 35 mm DIN rail or can be surface mountedPowerStandard: 115 VAC ±10%, 50/60 Hz, 2.5 W max.P option: 85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W typ.A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.D option: 9-30 VDC, 2.5 W typicalOptions—add to end of model numberL 1000 G with LO trip. Alarm trips on decreasing signal.HT 1000 G latching alarm with push button resetHP 1000 G latching alarm with power-off reset.Module power must be turned off to reset alarmsHH 1020 G with HI/HI trip. Alarms trip at their respectivetrip points on increasing signal.LL 1020 G with LO/LO trip. Alarms trip at their respectivetrip points on decreasing signal.A 1020 G with adjustable deadbands.R Reverse-acting alarms. Relay coils energized in an alarmcondition. No alarm condition with module power off.5A Shunt for 0-900 mADC to 0-5 ADC inputs. IncludesAPI 011 socket and 0.1 Ω 25W 1% shunt resistor.U Conformal coating for moisture resistanceAccessories—order as a separate line itemAPI 011 11-pin socket, DIN rail or surface mountAPI 011 FS 11-pin finger safe socket, DIN rail or surface mountAPI CLP1 Module hold-down spring for high vibration ormobile applicationsDC Input Alarm Trips, Factory Ranged API 1000 G, API 1020 GApplicationsDescriptionThe API 1000 G and API 1020 G are factory configured foreither a DC voltage or current input and provide alarm contactoutputs. Heavy duty relay contacts allow the module to directlycontrol high capacity loads.The API 1000 G provides a single setpoint adjustment andDPDT relay contacts. The alarm output can be factory config-ured for HI or LO operation, non-latching or latching, normalor reverse acting. Top-accessible potentiometers are used toadjust the alarm setpoint and deadband.The API 1020 G contains two independent setpoints with twoSPDT relay contact outputs. The alarm output can be factoryconfigured for HI/HI, HI/LO, LO/HI or LO/LO operation, normalacting or reverse acting. Top-accessible potentiometers areused to adjust each alarm setpoint. Deadband is fixed at 1% ofspan. Adjustable deadbands are optional.LoopTracker and Alarm Status LEDsAPI exclusive features include a LoopTracker LED that varies inintensity with changes in the process input signal.A red/green bi-color alarm status LED (two on the API 1020G) visually indicate alarm status. These LEDs provide a quickvisual picture of your process at all times.Output Test/UnlatchAPI’s exclusive functional test button can be used to verify thealarm and system operation. The output test button greatlyaids in saving time during initial startup and/or troubleshooting.The HT latching option provides the additional function ofunlatching the alarm when the reset button is pressed. Thealarm will reset if the alarm condition not longer exists.API 1020 G P 001 001115 VACYour Required InputYour Alarm Configuration2.75"Free FactoryI/O Setup!Quick Linkapi-usa.com/1000API 1000 GVariable Brightness Input LEDBi-Color Relay LEDDeadband AdjustmentSetpoint AdjustmentOutput Test ButtonReset w. HT Option2.38"1.75"API 1020 GA Option Deadband Adjustments2.38"1.75"Variable Brightness Input LEDBi-Color Relay 2 LEDBi-Color Relay 1 LEDSetpoint 2 AdjustmentSetpoint 1 AdjustmentOutput Test ButtonH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAHot SwappablePlug-In DesignAPI 011300 V RatingAPI 011 FS300 V Rating API CLP1© 08-18api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502ABSOLUTE PROCESS INSTRUMENTS |
Related manuals for Absolute Process Instruments API 1000 G
Absolute Process Instruments API 1005 G Quick Start Manual
Absolute Process Instruments API 1080 G Quick Start Manual
Absolute Process Instruments API 1040 G Series Quick Start Manual
Absolute Process Instruments APD 1200 Quick Start Manual
Absolute Process Instruments APD 1400 Quick Start Manual
Absolute Process Instruments APD 1431 Quick Start Manual
Absolute Process Instruments Cecomp F16ADA Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine