sigfox Repeater - Guide utilisateur / User guide version 1.0.022Page of 45ENFR4. Repeater monitoring with the sigfox backendWhen receiving the messages from a repeated sigfox device, you should get the following result on the sigfox backend:The repeated messages are identified by a percentage (red squares on the previous picture). For any given message sent by a sigfox device, thepercentage represents the portion of repetitions coming from the repeater.Repeater monitoring:To benefit from repeater monitoring, the adeunis sigfox Repeater must be visible from the Sigfox Cloud, so you have to declare it on the bac-kend. The simplest is to associate it with the contract of the objects which it must repeat. Repeater frames are free. To facilitate maintenance, itis advisable to enter the location of the repeater. Monitoring can be visual or programmed via the callback service repeater.In the MESSAGES page of your adeunis sigfox repeater, you should see the OOB frames from it:It contains the last information of:• VDD: the voltage of the battery (in Volt)• Repeated Messages: the number of repeated messages since the last status frame transmission• Unwanted devices: the number of unique devices not in the white list received since the last status frame transmission.• Unwanted messages: the range of sum of number of messages received from all devices not in the white list: not repeated messagessince the last status frame transmission• Wrong messages: the range of total number of malformed frames received since the last status frame transmission• Messages over regulation: the range of number of messages not repeated due to compliance with local regulation since the laststatus frame transmission