sigfox Repeater - Guide utilisateur / User guide version V1.0.029Page of 45ENFR5.3. Configuration through a terminal and AT CommandsA command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below for the syntax of AT com-mands available on the modem).Each command must finish with a “CR” or “CR” “LF” – both are acceptable.(CR indicates: Carriage Return, LF indicates: Line Feed)Once the command has been received, the modem will feedback: “Data” for ATS type playback control ?, AT/S or AT/V“O” , for any other command when this has been accepted.“E” , if it refuses the command due to a syntax error, unknown command, unknown range, invalid parameter, etc.“CM” , if it accepts the input in command modeThe available commands are:Command Description Comment+++ Enter Command mode CONNECTING... CMAT/V Display product version APP_8181AAA_PRG1701_V01.00.02:RTU_8120AAB_PRG_1701_V01.00.01AT/S Display registers list /ATS= Transfers the ‘m’ value to the regis-ter ‘n’«O» if Ok, «E» if error,«W» if coherency errorATS? Return content of register ‘n’ S= with as the registercontentAT&W Saves the current confguration tonon-volatile memory«O», «W» if coherency errorATO Exit command mode and return tooperation mode«O», «W» if coherency error5.4. Description of the registersON switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configurationhas not been changed).Commands such as Modification TTY= or ATR allow you to change the content of the registers: repre-senting the number of theregister and the value to be assigned. This latter is either a decimal value or a hexadecimal value consistent with the «encoding» columnof the tables below.Exemples :• ATS300=6 assigns the decimal value 6 in register 300• ATS302=2 assigns the hexadecimal value 0x02 in register 302It is imperative to save the parameters with the command AT&W before exiting the Command mode otherwise all changes will be lost.IMPORTANT: The registers that are not documented (that can appear in the list following the AT/S command) in theparagraphs that follow are reserved and must not be changed.The list of registers below allows you to change the behaviour of the product application.