sigfox Repeater - Guide utilisateur / User guide version V1.0.031Page of 45ENFRSeal1Position of the magnet forstarting up the productFastening clipFitting2Locking clips for theupper casing3/4Packing gland nut56.2. Closing the casingOnce previous stages have been carried out, you can close the casing of the sigfox RepeaterProcedure:1. Make sure that the seal is properly positioned on the base2. Clip the electronic board onto the casing’s base. Make sure that the fastening clip is properly locked into the board’s fitting.3. Insert the upper part of the casing. Inside this part there are guide rails for the board. Make sure that the board is properly positionedwithin these guides.4. Once the board is in position, lower the upper cover and lock it onto the casing’s base. Strong pressure will enable both parts to beclipped together and will enable protection level IP67 to be ensured.5. Finish the assembly by locking the packing gland’s nut in position6.3. Starting up the product using a magnetOnce the product has been configured and its assembly hasbeen finalised, the product is ready to be started up.The start-up is carried out using a magnet which you placeon the upper part of the product (cf. the diagram below). Themagnet must be held in position for at least 6 seconds so asto confirm the start-up of the product. When the magnet iswell detected, the green LED lights up for 1 second.Once the sigfox Repeater unit validates its start-up, itimmediately transmits status frames followed by a data frame(according the defined periodicity).