MODEL 300 COMBUSTION ANALYZERSPECIFICATIONSGENERALSize .................................... Carrying Case: 18" x 14" x 8"(45.7 x 35.6 x 20.3 cm)Standard Probe: 11.5" (29.2 cm)*Hose - 22' (6.7 m)*Weight ................................ 15 lbs. (6.8 kg)Materials ............................ HDPE Case, medium gray; polycarbonatemembrane switch; stainless steel probeCalibration Interval ........... 60 secondsStorage Environment ......... – 4 to 122°F (–20 to 50°C),0 to 100% relative humidityOperating Environment .... 32 to 104°F (0 to 40°C),0 to 99% relative humidity, non-condensing.Sample Gas Flow ............... 0.7 to 1.5 liters/minPower source ...................... Either 120 VAC, 240 VAC, or internal batterypack per sales orderBATTERY PACK SPECIFICATIONS(A battery-powered unit may be run off the charger, if required.)Output Voltage: .................. 5 VDCCharging Input Voltage: .... 8 VDC from Bacharach Charger(Refer to Section 6 for part numbers)Charging Time: .................. 5-6 hoursOperating Time ................. At least 200 sequential combustion tests, or 4to 6 hours (min.). The analyzer will operate anaddtional 1 hour (min.) after the BATTERYSTATUS light goes out. These discharge timesare based on worst-case-continuous-operatingconditions, which include printing every20 minutes. A typical discharge time of a fullycharged battery pack is between 12 and16 hours.iv Instruction 24-9223