www.baldormotion.com2-2 Introduction MN19192.2 Receiving and inspectionWhen you receive your MicroFlex, there are several things you should do immediately:1. Check the condition of the shipping container and report any damage immediately to thecarrier that delivered your MicroFlex.2. Remove the MicroFlex from the shipping container and remove all packing material. Thecontainer and packing materials may be retained for future shipment.3. Verify that the catalog number of the MicroFlex you received is the same as the catalognumber listed on your purchase order. The catalog number is described in the next section.4. Inspect the MicroFlex for external damage during shipment and report any damage to thecarrier that delivered your MicroFlex.5. If MicroFlex is to be stored for several weeks before use, be sure that it is stored in a locationthat conforms to the storage humidity and temperature specifications shown in section 8.1.14.2.2.1 Identifying the catalog numberThe MicroFlex is available with different current ratings. The catalog number is marked on theside of the unit. It is a good idea to look for the catalog number (sometimes shown as ID/No: )and write it in the space provided here:Catalog number: FMH______________-________Installed at: ________________________ Date: ______A description of a catalog number is shown here, using the example FMH2A03TR-EN23:Meaning AlternativesFMH MicroFlex family -2 Requires an AC supply voltage of 115-230 Volts, 1Φ or 3Φ -A03 Continuous current rating of 3A A01=1A; A06=6A;A09=9AT Built in AC power supply -R Requires external braking resistor -E Supported feedback types are encoder or SSI R=Resolver feedbackN No options specified -2 Serial port type is RS232 4 = RS4853 24VDC supply is required to power the control logic -