www.baldormotion.comSpecifications 8-5MN19198.1.8 Status output (X3)Unit All modelsUser supply (maximum) V 30Output current (max. continuous) mA 100FuseApproximate trip currentReset timemAs200<20Update interval ms 0.58.1.9 Incremental encoder feedback option (X8)Unit All modelsEncoder input A/B Differential, Z indexMaximum input frequency(quadrature)MHz 8Hall inputs Single ended, 5V logicOutput power supply to encoder 5V (±7%), 200mA max.Maximum recommended cable length 30.5m (100ft)8.1.10 SSI encoder feedback option (X8)Unit All modelsSSI encoder inputs Differential Data and ClockOperating mode(Baldor motors)Single turn.Positioning resolution up to262144 counts/rev (18-bit)Output power supply to encoder 5V (±7%), 200mA max.Maximum recommended cable length 30.5m (100ft)8.1.11 Resolver feedback option (X8)Unit All modelsResolutionset automatically by softwarebits 14Resolver winding ratio 0.5MicroFlex resolver input accuracy counts ±3Typical accuracyusing Baldor BSM series resolver motor (withinput set to simulate 4096 ppr)counts ±11Maximum recommended cable length 30.5m (100ft)