KBU 64 User Manual80-10100000-094–22To display the current time windows for each channel of your KBU 64type:1> WINDOW[CR]Channel 1 Slot 1 Slot 2 Slot 3 Slot 4On Off On Off On Off On Off********** ********** ********** ***********Monday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00Tuesday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00Wednesday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00Thursday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00Friday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00Saturday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00Sunday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00This display is specific to each channel. You must change the command lineprompt to ‘2>‘ to display the channel 2 window settings.1> SET WINDOW xxxy hh:mm HH:MM[CR]where:xxx is the first 3 letters of the day of the weeky is the window slot number (1 to 4)hh:mm is the time in hours and minutes when thebackup is enabled, (on xxxday)HH:MM is the time in hours and minutes from whichthe backup becomes disabled, (on xxxday)For example:1> SET WINDOW MON1 08:00 13:00[CR]This will restrict the possibility of using backup operation of the channel 1leased circuit, to between 08:00 to 13:00 on Mondays. This has noeffect on a backup request made on any day other than a Monday. Youcan use the same command procedure to action restrictions at othertimes on the same day, or other days of the week:1> SET WINDOW MON2 14:00 19:00[CR]This will provide the additional possibility of using backup operation ofthe channel 1 leased circuit, to between 14:00 to 19:00 on Mondays.If you set both the ‘hh:mm’ and ‘HH:MM’ to 00:00 then that particularslot on that day will be turned off and not used. If you set both the