5–28INSTALLATIONCOPYRIGHT © 1998 CANON INC. CANON NP6621 REV.0 FEB. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)B. Installation to the CopierCaution:This model may not be available for sale insome areas.Caution:Keep the following in mind when installing theRDD to the copier:1. This Accessory is to be installed by a qualifiedpersonal.2. Make sure the copier has been properly in-stalled before starting the work.3. Keep the copier’s power cord disconnectedduring the work.4. Be sure to use the appropriate screws (length,diameter).5. Make sure the computer in the service stationhas been properly loaded with the RDD’s set-tings data.1) Remove the two screws w to detach the RDD’stop cover q.Fig. 5-8022) Connect the Power Supply Unit’s connector eto the RDD’s connector r as shown.Fig. 5-803VIII.INSTALLING THE RE-MOTE DIAGNOSTICDEVICE IIA. UnpackingFig. 5-801q RDD ....................................................... 1 unitw Power Supply Unit ................................. 1 unite Screw (M4×6) ........................................ 4 pcs.r Harness band ........................................ 2 pcs.t Switch setting label ................................ 1 pcs.y Grounding wire* ..................................... 1 pc.u Ferrite core ............................................ 1 pc.*Not used.uqtw eryrewq wDownload service manual and resetter printer at http://printer1.blogspot.com