127By linking two types of events, a single event is triggered. Select AND/OR for the event linking method.Able to set the operations to perform, such as recording video or sending e-mail notifications, when a linked event istriggered.Note• Able to check the linked event status on the [Event and Input/Output Menu] of the Camera Viewer (P. 51).Linked Event 1 to 4Able to register up to four linked events.It is possible to link the following events: [Volume Detection], [External Device Input], [Timer] and [Intelligent Function].[Linked Event]Select whether to use a linked event.[Event Linking Method]Select the event linking conditions.When [AND] is set, a new linked event is triggered if both event types selected with [Event 1] and [Event 2] are triggered. Inthis case, set [Event Order] and [Event Gap].When [OR] is set, a new linked event is triggered if either event type selected with [Event 1] or [Event 2] is triggered.[Event Order]Able to select the trigger order of two events when [Event Linking Method] is set to [AND].If set to [None], the order will not be considered.[Event Gap (seconds)]Enter the trigger interval between two events when [Event Linking Method] is set to [AND].A new linked event is triggered if the second event triggers within the specified interval after the first event was triggered. Event 1, 2Specify the two events to be linked. The settings are the same for both.[Event Type]Select the event type for linking.[Volume Detection]Select an ON event or an OFF event in [Volume Detection Status] to trigger a linked event .[External Device Input]For [External Device Input], select the external device input to use.Select an active event or inactive event to trigger a linked event in [External Device Input Status].[Event] > [Linked Event]HM4x