Chapter 1515-2015.5.8 <016: time length to first response at time of fax/tel switchover> 0017-6108iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iAllows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel switching function is operating.15.5.9 <017: pseudo RBT signal pattern ON time length><018: pseudo RBT signal pattern OFF time length (short)><019:pseudo RBT signal pattern OFF time length (long)> 0017-6109iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iUse it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.15.5.10 <020: pseudo CI signal pattern ON time length><021: pseudo CI signal pattern OFF time length (short)><022:pseudo CI signal pattern OFF time length (long)> 0017-6110iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iUse it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.15.5.11 <023: CNG detention level for fax/tel switchover> 0017-6111iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iUse it to set the CNG detention level for a fax/tel switchover.15.5.12 <024: pseudo RBT transmission level at time of fax/tel switchover> 0017-6112iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iUse it to set the pseudo transmission level for a fax/tel switchover.15.5.13 <025: Answering machine connection function signal detection time> 0017-6113iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iSets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.15.5.14 <027: V.21 low-speed flag preamble identification length> 0017-6114iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iUse it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific periodof time.15.5.15 <055: Acquisition period of environmental log data> 0017-8531iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iUse it to change the acquisition period of environmental log data.15.5.16 <056 - 061: Count type select > 0017-6115iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iUse it to confirm the count type indicated on the Counter Check screen, which appears in response to a press on the Counter key.When '0' is selected, count type will not be indicated.No.56: Use it to indicate the type of software counter 1 of the control panel. The type of soft counter 1 cannot be changed.No.57: Use it to change the type of soft counter 2* of the control panel to suit the needs of the user.No.58: Use it to change the type of soft counter 3* of the control panel to suit the needs of the user.No.59: Use it to change the type of soft counter 4* of the control panel to suit the needs of the user.No.60: Use it to change the type of soft counter 5* of the control panel to suit the needs of the user.No.61: Use it to change the type of soft counter 6* of the control panel to suit the needs of the user.*:The default type settings of soft counter is different from models.The soft counters are classified a follows in terms of input numbers:100s: total200s: copy300s: print400s: copy + print500s: scan700s: received file print800s: report pint900s: transmitted scanGuide to the Table- 1:Count sheets of all sizes by one.- 2:Count sheets of the large size by two.- C:full color- Bk:black mono- L:large size (larger than A4/LTR)- S:small size (A4/LTR or smaller)MEMO:To make a change so that B4 papers (for print) will be counted as large-size, use service mode: make the following selections, and change bit 0 to '1': #SSSW>SW33.To make a change so that B4 papers (for scan) will be counted as large-size, use service mode: make the following selections, and change bit 2 to '1': #SSSW>SW33.