Chapter 1515-24Specify whether to output an image for ADF perpendicularity adjustment.15.6.2 Numeric Parameter Functional configuration 0017-6117iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i4 Outputting an Image for ADF PerpendicularityAdjsutmentoutput not output5 Not used - -6 Not used - -7 Not used - -No. Function Default Setting range Unit001: - 023: Not used024: CIS scan position during ADF scanning. 385 300-450 one unit=0.1mm025: Not used026: Distance from the standby position of CIS to theshading start point.22 6-48 one unit=0.1mm027: - 030: Not used031: Vertical scan start position adjustment 35 0-70 one unit=0.1mm032: Horizontal scan start position adjustment 115 50-150 one unit=0.1mm033: Vertical scan magnification correction 16 0-32 one unit=0.1%034: Not used035: - 036: Reader motor speed adjustment 474037: - 040: Not used041: Vertical scan start position adjustment (scanningon ADF)35 0-70 one unit=0.1mm042: Horizontal scan start position adjustment(scanning on ADF)220 170-270 one unit=0.1mm043: Horizontal scan end position correction(copy:scanning on ADF)24 0-200 one unit=0.1mm044: Horizontal scan end position correction(superfine:scanning on ADF)36 0-200 one unit=0.1mm045: Horizontal scan end position correction(fine:scanning on ADF)47 0-200 one unit=0.1mm046: Horizontal scan end position correction(standard:scanning on ADF)47 0-200 one unit=0.1mm047: Vertical scan magnification correction (scanningon ADF)16 0-32 one unit=0.1%048: Horizontal scan magnification correction(scanning on ADF)16 0-32 one unit=0.1%049: - 053: Not used054: Pickup motor speed correction (when the ADF isused)16 0-32 one unit=0.1%055: - 192: Not usedBit Function 1 0