Chapter 1515-25If any operation error occurs after changing the setting value, change the setting value to the original one.15.6.3 <024:CIS scan position during ADF scanning> 0017-6118iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iThis value is used when automatic scan position adjustment (TESTMODE>"2"SCAN TEST>"3"SHEET POS ADJ) fails.15.6.4 <026:Distance from the standby position of CIS to the shading start point> 0017-6119iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iWhite shading can be adjusted finely.Normally, do not change the setting value. If any operation error occurs after changing the setting value, change the setting value to the original one.15.6.5 <031Vertical scan start position adjustment> 0017-6120iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iAdjust the position at which vertical scanning of a book starts. The larger the adjustment value, the narrower the left-side margin of the image becomes.15.6.6 <032Horizontal scan start position adjustment> 0017-6121iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iAdjust the position at which horizontal scanning of a book starts. The larger the adjustment value, the narrower the top margin in the image becomes.15.6.7 <033Vertical scan magnification correction> 0017-6122iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iCorrect the magnification of vertical scanning of a book. The larger the adjustment value, the more the image stretches in the vertical scanning direction.15.6.8 <035: - 036:Reader motor speed change> 0017-6123iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iThough no market adjustment work needs to be carried out, enter factory defaults at image processor PCB replacement.193: ADF special paper, standardized size: LGLmisidentification-ready0 0 : LEGAL1 : FOOLSCAP2 : M_OFFICIO3 : A_FOOLSCAP4 : FOLIO5 : G_LEGAL6 : A_OFFICIO7 : B_OFFICIO194: ADF special paper, standardized size: LTRmisidentification-ready0 0 : LTR1 : G_LTR2 : A_LTR195: ADF special paper, standardized size: LTR_Rmisidentification-ready0 0 : LTR_R1 : FOOLSCAP2 : OFFICIO3 : E_OFFICIO4 : G_LTR_R5 : A_LTR_R196: shading target value (red) 272 0-511197: shading target value (green) 272 0-511198: shading target value (blue) 272 0-511199: - 212: Not used213: XYZ correction value (X) of standard white plate 8273 1-9999214: XYZ correction value (Y) of standard white plate 8737 1-9999215: XYZ correction value (Z) of standard white plate 9427 1-9999216: - 350: Not usedNo. Function Default Setting range Unit