Chapter 1616-116.1 Error Code Details16.1.1 E000 to E197 (DC Controller) 0019-7440iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245NT-16-1Code Cause RemedyE000 The temperature of the fixing assembly is abnormally high.0001 While startup control is under way, the reading of the main thermistoris less than 30 deg C continuously for 200 msec or more 1 sec afterthe start of power supply.While startup control is under way, the reading of the main thermistoris less than 70 deg C continuously for 200 msec or more 2 sec afterthe start of power supply.While startup control is under way, the reading of the main thermistoris less than 120 deg C continuously for 200 msec 6 sec after the startof power supply.The startup control does not end 30 sec after the start of power supply.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.Replace the DC controller PCB.E001 The temperature of the fixing assembly is abnormally high.0000 The reading of the main thermistor is 250 deg C or more continuouslyfor 200 msec.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.Replace the DC controller PCB.0001 The hardware circuit detects overheating of the main or subthermistor for 200 msec.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace the DC controllerPCB.0002 The reading of the sub thermistor is 295 deg C or more continuouslyfor 200 msec.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace the sub thermistor.Replace the DC controller PCB.E002 The rise in temperature of the fixing assembly is faulty.0000 While startup control is under way, the reading of the main thermistoris less than 115 deg C continuously for 400 msec 1.3 sec after it hasindicated 100 deg C.While startup control is under way, the reading of the main thermistoris less than 150 deg C continuously for 400 msec 1.3 sec after it hasindicated 140 deg C.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.Replace the DC controller PCB.E003 The fixing temperature is too low after a standby state.0000 While regular temperature control is under way, the reading of themain thermistor is less than 140 deg C continuously for 400 msec ormore.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.Replace the DC controller PCB.E004 Failure in main/sub thermistor0000 When disconnection is detected with connector of the main/subthermistor for 30 sec continuously while DC controller is working.Clear the error in Service Mode: COPIER > FUNCTION > CLEAR> ERR. Replace the main thermistor (film unit). Replace DCcontroller PCB.E007 The rotation of the fixing film is faulty.0000 While the fixing motor is rotating, the marker signal is not detectedfor 6 sec with the reading of the main thermistor indicating 100 degC or more.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.Replace the DC controller PCB.E010 The rotation of the main motor is faulty.0001 Detection is executed every 100 msec after the start of motor rotation;however, the drive detection signal is absent for 2 sec.Replace the main motor. Replace the DC controller PCB.0002 During motor rotation, detection is executed every 100 msec;however, the drive signal is absent 5 times in sequence.Replace the main motor. Replace the DC controller PCB.E014 The rotation of the fixing motor is faulty.0001 Detection is executed every 100 msec after the start of motor rotation;however, the drive detection signal is absent for 2 sec.Replace the fixing motor. Replace the DC controller PCB.0002 During motor rotation, detection is executed every 100 msec;however, the drive signal is absent 5 times in sequence.Replace the fixing motor. Replace the DC controller PCB.E019 The waste toner case is full, or the waste toner case full sensor is faulty.0000 When the waste toner case is identified as being full for 2000 printscontinuously, an alert is issued; thereafter, the case is identified asbeing full continuously for 100 prints.Replace the waste toner sensor. Replace the DC controller PCB.E020 The path between the sub hopper and the developing assembly is clogged with toner.0000 The developing assembly toner sensor detects the absence of toner,while the sub hopper toner sensor detects the presence of toner. Withthe developing clutch turned on, the hopper feedscrew motor isrotated for 1 sec intermittently 194 times; still, the developingassembly toner sensor does not detect the presence of toner.Replace the developing assembly toner sensor. Replace the subhopper toner sensor. Replace the DC control PCB.E024 The developing assembly connector is disconnected/Disconnection of Toner sensor.0000 The developing assembly toner sensor connection detection signal isabsent for 100 msec 10 times in sequence.Replace the developing assembly toner sensor. Connect theconnector. Replace the DC controller PCB.