CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual- 18 -#Configure an ip address for the WAN portsrcnet 172.16.1.1 255.255.255.0#Configure an ip address and gateway for the NMS portipset 192.168.1.11 255.255.255.0 172.16.1.2#Enable LAN port and set the bandwidth to 400Kbps.lanset 1 7#Save the configurationcsaveScript for setting CPE site configuration back to default Igcisrcnet 172.16.1.2 255.255.255.0ipset 192.168.2.11 255.255.255.0 172.16.1.1lanset 1 7csaveB) Script for resetting CL-MC-XE1-IP-Y to default IIScript for setting the device back to default II(Enable E1 port#1 and set LAN bandwidth to 400 kbps)Script for setting CO site configuration back to default IIgcisrcnet 172.16.1.1 255.255.255.0ipset 192.168.1.11 255.255.255.0 172.16.1.2#Set both transmitting and receiving pseudowire ID to 1 for E1 port#1cespwidset 1 1 1#Set the transmit packet size to 782 byte for E1 port#1#Usage: pktsize ch_no pkt_size(0~3) !#pkt_size(total len)=> (0: 1514 Byte, 1:782 Byte,# 2: 178 Byte, 3: 306 Byte)pktsize 1 1#Set the jitter buffer depth to 11.5 msec for E1 port#1#Usage: jitterbd ch_no depth !#depth(pktsize=0)(0: 11 ms, 1: 23 ms, 2: 40 ms, 3: 75 ms,www.carelink.com