1413All the electrical connections must be carried out by qualified installers and all the wirings must beconnected according to the wiring diagram.Make ground connection prior to any other electrical connections.All power sources must be turned off before wiring work and do not turn on the power until you have madesure all the wirings have been safety checked.A main switch and circuit breaker or fuse must be installed, the capacity should be above 1.5 times ofmaximum current in circuit.An individual branch circuit and single socket used only for this appliance must be available.Wire cross section is depending on the rated current and national, state and local electrical wiring code.Consult local building codes and National electrical code for special requirement.If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarlyqualified persons in order to avoid a hazard.The unit must be connected to the main power supply by means of a circuit breaker or a switch with acontact separation of at least 3mm in all poles. Installation of a residual current device (RCD) having arated residual operating current not exceeding 30mA is advisable.This appliance incorporates an earth connection for functional purposes only.CAUTIONNOTICE:1. All power wires must be sized in according with national,state and local electrical wiring code. Consult localbuilding codes and National Electrical Code for special requirements.2. The outdoor power cord and interconnecting cable type should be H07RN-F.3. The rated current of appliance is indicated on the nameplate.4. The specification of outdoor unit fuse is T20A/250VAC (applicalbe to units adpot R32 refrigerantonly) Note: The fuse is made of ceramic.60mm40mm10mmPower input cordGND60mm40mm10mmGNDConnective CableW 1 2 3 L NPower InputTo IndoorW 1 2 3To outdoorQHP009QHP012Outdoor UnitIndoor UnitModel5. WIRING38QHP009E8S38QHP012E8S10.013.01620Model Rated Current(A) Fuse Rating(A) Power input cord Connective Cable3*1.5mm3*1.5mm5*1.5mm5*1.5mm(with Min. Crosse section) (with Min. Crosse section)5. WIRING1 2 332 L N1Y/G4cm 4cmMagnetic ring(if supplied and packed with the accessories)Magnetic ring(if supplied and packedwith the accessories)Pass the belt through the hole of theMagnetic ring to fix it on the cablePass the belt throughthe hole of the Magneticring to fix it on the cableMagnetic ring installationMagnetic ringIndoor unitOutdoor unitFor example:The terminal block may be different according to the models.GB