111APPENDIX B — NAVIGATOR™ DISPLAY TABLES (cont)MODE — OUTPUTSMODE — CONFIGURATIONITEM EXPANSION UNITS RANGE COMMENT WRITESTATUS CCN TABLE CCN POINT PAGENO.CIR.A CIRCUIT A OUTPUTSCP.A Compressor A Relay OFF/ON CIRCA_D CP_AHT.A Oil Heater Circuit A OFF/ON OIL_HT_ASL1.A Slide Valve 1 Cir A OFF/ON SLID1_ASL2.A Slide Valve 2 Cir A OFF/ON SLID2_AOLS.A Oil Solenoid Cir A OFF/ON OIL_SL_AHGB.A Hot Gas Bypass Cir A OFF/ONFAN.A Circuit A Fan Stages X 0-6 CIRCA_D FAN_ST_ASPD.A Circ A Varifan Position XXX (%) 0-100 CIRCA_AN hd_pos_aEXV.A Circuit A EXV % Open XXX (%) 0-100 CIRCA_AN EXV_A 61ECO.A Circ A EXV ECO % Open XXX (%) 0-100 EXV_EC_ADGT.A DGT Cool Solenoid A OFF/ON dgt_gascool_aCIR.B CIRCUIT B OUTPUTSCP.B Compressor B Relay OFF/ON CIRCB_D CP_BHT.B Oil Heater Circuit B OFF/ON CIRCB_D OIL_HT_BSL1.B Slide Valve 1 Cir B OFF/ON SLID1_BSL2.B Slide Valve 2 Cir B OFF/ON SLID2_BOLS.B Oil Solenoid Cir B OFF/ON OIL_SL_BHGB.B Hot Gas Bypass Cir B OFF/ONFAN.B Circuit B Fan Stages X 0-6 CIRCB_D FAN_ST_BSPD.B Circ B Varifan Position XXX (%) 0-100 CIRCB_AN hd_pos_bEXV.B Circuit B EXV % Open XXX (%) 0-100 CIRCB_AN EXV_B 61ECO.B Circ B EXV ECO % Open XXX (%) 0-100 EXV_EC_BDGT.B DGT Cool Solenoid B OFF/ON dgt_gascool_bCIR.C CIRCUIT C OUTPUTSCP.C Compressor C Relay OFF/ON CIRCC_D CP_CHT.C Oil Heater Circuit C OFF/ON CIRCC_D OIL_HT_CSL1.C Slide Valve 1 Cir C OFF/ON SLID1_CSL2.C Slide Valve 2 Cir C OFF/ON SLID2_COLS.C Oil Solenoid Cir C OFF/ON OIL_SL_CHGB.C Hot Gas Bypass Cir C OFF/ONFAN.C Circuit C Fan Stages X 0-6 CIRCC_D FAN_ST_CSPD.C Circ C Varifan Position XXX (%) 0-100 CIRCC_AN hd_pos_cEXV.C Circuit C EXV % Open XXX (%) 0-100 CIRCC_AN EXV_CECO.C Circ C EXV ECO % Open XXX (%) 0-100 EXV_EC_CDGT.C DGT Cool Solenoid C OFF/ON dgt_gascool_cGEN.O GENERAL OUTPUTSPMP.1 Water Exchanger Pump 1 OFF/ON STATEGEN CPUMP_1PMP.2 Water Exchanger Pump 2 OFF/ON STATEGEN CPUMP_2PMP.3 Condenser Pump 1 OFF/ON STATEGEN HPUMP_1CO.HT Cooler Heater Output OFF/ON STATEGEN COOLHEATBVL.A Ball Valve Position A OPEN/CLOSE ref_iso_aBVL.B Ball Valve Position B OPEN/CLOSE ref_iso_bBVL.C Ball Valve Position C OPEN/CLOSE ref_iso_cCN.HT Condenser Heat Output OFF/ON Not supported. RECLAIM cond_htrREDY Chiller Ready Status OFF/ON forcible RECLAIM READYRUN Chiller Running Status OFF/ON forcible STATEGEN RUNNINGSHUT Customer Shutdown Stat OFF/ON forcible STATEGEN SHUTDOWNCATO Chiller Capacity 0-10 v XX.X forcible STATEGEN CAPT_010ALRM Alarm Relay OFF/ON STATEGEN ALARMALRT Alert Relay OFF/ON STATEGEN ALERTITEM EXPANSION UNITS RANGE COMMENT DEFAULT CCNTABLECCNPOINT PAGE NO.DISP DISPLAY CONFIGURATIONTEST Test Display LEDs OFF/ON OFF N/A display_testMETR Metric Display US/METR US DISPCONF DISPUNITLANG Language Selection EnglishEspanolFrancaisPortuguesTranslatedEnglish DISPCONF LANGUAGE 8