ProgrammingService Instructions 755 A/756 A - 00.0 - 02/2019 343Valve Y32 Valve Y124Mode Method Position Blowing ON BlowingOFF Position Blowing ON BlowingOFF SequenceMode 0 - active - active Function offMode 1 A-B-F Blow tubein foldingplateFolding plateclosedNeedlesONBlow tube in flapclampsFlap clampsclosedNeedles ON Blow pocket bag and/or piping to the seam begin-ning simultaneously.Mode 2 A-B-F Blow tubein foldingplateFolding plateclosedFlapclampsclosedBlow tube in flapclampsFlap clampsclosedNeedles ON Blow pocket bag and piping alternately up toseam beginning.Mode 3 B-F Blow tubein foldingplateLower folder 10 mmafter load-ing posi-tionBlow tube in flapclampsFlap clampsclosed10 mm afterloading posi-tionBlow pocket bag and/or piping briefly.Blow piping already while folder is lowering.Mode 4 B-F Blow tubein foldingplateLower folder FlapclampsclosedBlow tube in flapclampsFlap clampsclosedNeedles ON Blow pocket bag and piping alternately up toseam beginning. Blow piping already while folderis lowering.Mode 5 B Blow tubein flapclamp rightFlap clampclosedNeedlesONBlow tube in flapclamp left5 mm after load-ing positionNeedles ON Blow pocket on flap.Mode 6 A-B-F Blow tubein foldingplateFolding plateclosed180 mmafter load-ing posi-tionBlow tube in flapclampsFlap clampsclosedNeedles ON Blow pocket bag and/or piping at the same time.Blow piping after path.Mode 7 A-B-F Blow tubein foldingplate20 mm afterloading posi-tion180 mmafter load-ing posi-tionBlow tube in flapclamps10 mm afterloading position180 mm afterloading posi-tionBlow pocket bag and/or piping after paths.