SiBE07-618_Ciii Table of Contents2.1 Remote Controller ..................................................................................452.2 AUTO · DRY · COOL · HEAT · FAN Operation ......................................462.3 POWERFUL Operation ..........................................................................482.4 OUTDOOR UNIT QUIET Operation.......................................................492.5 HOME LEAVE Operation .......................................................................502.6 TIMER Operation ...................................................................................52Part 6 Service Diagnosis............................................................. 541. Caution for Diagnosis............................................................................551.1 Troubleshooting with LED ......................................................................552. Problem Symptoms and Measures .......................................................563. Service Check Function ........................................................................574. Troubleshooting ....................................................................................604.1 Error Codes and Description ..................................................................604.2 Indoor Unit PCB Abnormality .................................................................614.3 Freeze-up Protection Control or Heating Peak-cut Control....................624.4 Fan Motor (AC motor) or Related Abnormality.......................................644.5 Thermistor or Related Abnormality (Indoor Unit)....................................654.6 Signal Transmission Error (between Indoor Unit and Outdoor Unit) ......664.7 Unspecified Voltage (between Indoor Unit and Outdoor Unit) ...............674.8 Outdoor Unit PCB Abnormality...............................................................684.9 OL Activation (Compressor Overload) ...................................................694.10 Compressor Lock ...................................................................................704.11 DC Fan Lock ..........................................................................................714.12 Input Overcurrent Detection ...................................................................724.13 Four Way Valve Abnormality..................................................................734.14 Discharge Pipe Temperature Control.....................................................754.15 High Pressure Control in Cooling ...........................................................764.16 Compressor System Sensor Abnormality ..............................................774.17 Position Sensor Abnormality ..................................................................784.18 CT or Related Abnormality .....................................................................804.19 Thermistor or Related Abnormality (Outdoor Unit).................................824.20 Electrical Box Temperature Rise............................................................844.21 Radiation Fin Temperature Rise ............................................................864.22 Output Overcurrent Detection ................................................................884.23 Refrigerant Shortage ..............................................................................904.24 Low-voltage Detection or Over-voltage Detection..................................924.25 Signal Transmission Error (on Outdoor Unit PCB).................................935. Check ....................................................................................................945.1 How to Check .........................................................................................94Part 7 Removal Procedure ........................................................ 1011. Outdoor Unit........................................................................................1021.1 Removal of Outer Panels .....................................................................1021.2 Removal of Outdoor Fan / Fan Motor...................................................1061.3 Removal of Electrical Box ....................................................................1101.4 Removal of PCB...................................................................................1151.5 Removal of Sound Blanket / Thermistors.............................................1181.6 Removal of Four Way Valve.................................................................1201.7 Removal of Electronic Expansion Valve...............................................121