Installation manual22 EKHVWQ002AAV3 + EKHHS200+260AA1V3Domestic hot water heat pump4PW65342-1A – 10.2010Field settings tableFirstcodeSecondcode Setting nameInstaller setting at variance with default value Defaultvalue Range Step UnitDate Value Date Value0 Different operation modes00 Powerfull operation mode temperature set point 40 35~50 1 °C01 Disinfection operation mode tempeature set point 60 55~75 1 °C02 Temperature setpoint: reheat minimumtemperature 40 35~75 1 °C03 Temperature setpoint: reheat maximumtemperature 45 35~75 1 °C04 Status: defines whether the reheat operation isturned ON(1) or OFF(0) 0 (OFF) 0/1 1 —1 Automatic domestic hot water tank temperature set point calculation00 Renewal time for set point calculation 6:00 0:00~23:30 0:30 hour01 Mnimum automatic temperature set point 42 35~75 1 °C02 Maximum automatic temperature set point 60 35~75 1 °C2 Disinfection operation00 Operation interval Fri Mon~SunAll — —01 Status 1 (ON) 0/1 1 —02 Start time 23:00 0:00~23:00 1:00 hour03 Status 0 (OFF) 0/1 1 —04 Interval 32 5~60 1 minute3 Miscellaneous00 Auto restart 1 (ON) 0/1 1 —01 User permission level 3 2/3 1 —02 Status 0 (OFF) 0/1 1 —03 Status 0 (OFF) 0/1 1 —4 Miscellaneous03 Simultanuous operation of booster heater andheatpump 0 0/1/2/3 1 —04 Not applicable. Do not change the default value. 16 Miscellaneous00 Start 10 2~20 1 °C01 Stop 0 0~10 1 °C02 Booster heater economical timer 0 0~95 5 minute03 Powerful mode priority 1 (ON) 0/1 1 —04 Quiet mode level 1 1/2/3 1 —7 Miscellaneous01 Domestic hot water step length 2 2~40 1 °C02 Not applicable. Do not change the default value. 303 Not applicable. Do not change the default value. 004 T-ambient 2 –25~+10 1 °C8 Automatic setpoint calculation00 Set point (weekdays) 45 35~75 1 °C01 Set point (week-end) 50 35~75 1 °C02 Initial city water temperature 15 0~30 1 °C03 Reset demand 0 (OFF) 0/1 1 —04 Domestic hot water tank volume 0 (260 l) 0/1) 1 —D Benefit kWh rate power supply/Local shift value weather dependent01 Benefit kWh rate power supply 0 0/1/2 1 —E Unit information readout00 Readout of the software version — Read only — —01 Readout of the EEPROM version — Read only — —02 Readout of the unit model identification — Read only — —