EKHVWQ002AAV3 + EKHHS200+260AA1V3Domestic hot water heat pump4PW65342-1A – 10.2010Installation manual2714. IMPORTANT INFORMATION REGARDING THEREFRIGERANT USEDThis product contains fluorinated greenhouse gases covered by theKyoto Protocol. Do not vent gases into the atmosphere.Refrigerant type: R410AGWP(1) value: 1975(1) GWP = global warming potential15. DISPOSAL REQUIREMENTSDismantling of the unit and treatment of parts must be done inaccordance with relevant local and national legislation.16. UNIT SPECIFICATIONS16.1. Technical specifications EKHVWQ002AAV316.2. Electrical specifications EKHVWQ002AAV316.3. Specifications EKHHS200+260AA1V3H9 Ambient temperature thermistorfailure (ambient thermistor isbroken)Contact your local dealer.HC Domestic hot water tankthermistor failureContact your local dealer.J3 Discharge pipe thermistor failure Contact your local dealer.J6 Aircoil thermistor frost detectionfailureContact your local dealer.L3 Electric component failure Contact your local dealer.L4 Electric component failure Contact your local dealer.L5 Electric component failure Contact your local dealer.P4 Electric component failure Contact your local dealer.U0 Refrigerant failure (due torefrigerant leak)Contact your local dealer.U2 Main circuit voltage failure Contact your local dealer.U4 Communication failure Contact your local dealer.U5 Communication failure Contact your local dealer.UA Communication failure Contact your local dealer.INFORMATIONNational implementation of EU regulation on certainfluorinated greenhouse gases may require to provide theappropriate official national language on the unit.Therefore, an additional multilingual fluorinatedgreenhouse gases label is supplied with the unit.Sticking instructions are illustrated on the backside of thatlabel.Errorcode Failure cause Corrective actionNominal capacity (kW) 2.5Casing material Pre-coated sheet metalDimensions H x W x D (mm) 730 x 600 x 595Weight• with packaging (kg) 153• without packaging (kg) 144Connections• water inlet/outlet Quick coupling• water drain drain valvePump• type AC motor• no. of speed position IIISound pressure level(a)(a) At 1 m in front of the unit (free field condition)(dBA) 47 dBAInternal water volume (l) 1Operation range - water side (°C) 35~75 (b)(b) Temperatures above 60°C are achieved by booster heater.Operation range - ambient air• domestic hot water (°C) +2~+35 (c)(c) field settingPhase 1N~Frequency (Hz) 50Voltage range• minimum (V) 220• maximum (V) 240Voltage tolerance –10%/+6%Maximum running current (A) 17.4Recommended field fuse (A) 20EKHHS200 EKHHS260Storage capacity (l) 200 260Material Stainless steelOverall dimensions H x W x D (mm) 1235 x 600 x 695 1510 x 600 x 695Connections G 1/2" MBSP(a)(a) MBSP = Male British Standard PipeInspection opening (mm) Wrench 41Weight (empty) (kg) 57 66Mounting On top of EKHVWQ002AAV3(b)(b) For floor standing next to the heat pump module, the EKFMHHSAA kit is needed.Maximum pressure domestichot water tank(bar) 10Maximum primary workingpressure (heating side)(bar) 10Maximum tempreaturedomestic hot water(°C) 75Booster heater• Power supply 230 V 50 Hz 1~• Running current (A) 7• Capacity (kW) 1.5