Functions SiUS0411112 List of Functions1. FunctionsCategory FunctionsFTXN09/12KEVJURKN09/12KEVJUFTXN09/12KEVJURXN09/12KEVJUCategory FunctionsFTXN09/12KEVJURKN09/12KEVJUFTXN09/12KEVJURXN09/12KEVJUBasic Function Inverter (with Inverter Power Control) Health &Clean Air-Purifying Filter — —Operation Limit for Cooling (°FDB) 50 ~114.850 ~114.8 Photocatalytic Deodorizing Filter — —Operation Limit for Heating (°FWB) — 5 ~64.4 Air-Purifying Filter with PhotocatalyticDeodorizing Function — —PAM Control Titanium Apatite PhotocatalyticAir-Purifying Filter Standby Electricity Saving Compressor Oval Scroll Compressor — — Air Filter (Prefilter) Swing Compressor Wipe-Clean Flat Panel Rotary Compressor — — Washable Grille — —Reluctance DC Motor MOLD PROOF Operation — —ComfortableAirflowPower-Airflow Louver (Horizontal Blade) Good-Sleep Cooling Operation — —Power-Airflow Dual Louvers — — Timer WEEKLY TIMER — —Power-Airflow Diffuser — — 24-Hour ON/OFF TIMER Wide-Angle Fins (Vertical Blades) NIGHT SET Mode Vertical Auto-Swing (Up and Down) Worry Free“Reliability &Durability”Auto-Restart (after Power Failure) Horizontal Auto-Swing (Right and Left) — — Self-Diagnosis (Digital, LED) Display 3-D Airflow — — Wiring Error Check Function — —COMFORT AIRFLOW Operation Anti-Corrosion Treatment of OutdoorHeat Exchanger ComfortControlAuto Fan Speed Flexibility Multi-Split / Split Type CompatibleIndoor Unit — —Indoor Unit Quiet Operation NIGHT QUIET Mode (Automatic) — — H/P, C/O Compatible Indoor Unit Outdoor Unit Quiet Operation (Manual) — — Flexible Power Supply Correspondence — —INTELLIGENT EYE Operation — — Chargeless 32.8 ft 32.8 ftQuick Warming Function(Preheating Operation) — Either Side Drain (Right or Left) Hot-Start Function — Power Selection — —Automatic Defrosting — Low Temperature Cooling Operation(–15°C) (5°F) Operation Automatic Operation — Program Dry Function °F/°C Changeover R/C TemperatureDisplay (factory setting : °F) Fan Only RemoteControl 5-Room Centralized Controller (Option) LifestyleConvenience New POWERFUL Operation(Non-Inverter) — — Remote Control Adaptor(Normal Open-Pulse Contact) (Option) Inverter POWERFUL Operation Remote Control Adaptor(Normal Open Contact) (Option) Priority-Room Setting — —COOL / HEAT Mode Lock — — DIII-NET Compatible (Adaptor) (Option) HOME LEAVE Operation — — RemoteController Wireless ECONO Operation Wired (Option) Indoor Unit ON/OFF Button Signal Receiving Sign R/C with Back Light Temperature Display — —Note: : Holding Functions— : No Functions