SiUS041111 Piping DiagramsAppendix 2311.2 Outdoor UnitRKN09/12KEVJURKN15/18/24KEVJUOUTDOOR UNITHEAT EXCHANGER9/32CuT9/32CuT3/8CuT3/16CuT 1/4CuT 1/4CuT3/16CuTMPROPELLER FAN1/4CuT3/8CuTSTRAINERFIELD PIPING3/16CuT(1/4CuT)3/8CuT1/4CuTREFRIGERANT FLOWMUFFLER MUFFLER FIELD PIPING3/8CuT COOLINGCOMPRESSOR (3/8CuT)ACCUMULATORMOTOR OPERATEDVALVELIQUID STOPVALVEGAS STOPVALVEDISCHARGE PIPETHERMISTORHEAT EXCHANGERTHERMISTORMUFFLERWITHFILTERFANMOTOR3D065937AOUTDOOR UNIT(8.0) HEAT EXCHANGER5/16CuT5/16CuT(16.0)5/8CuT5/16CuT(12.0)15/32CuT CAPILLARY TUBE 15/16CuT 5/16CuT 5/32CuT(8.0) (4.0)5/16CuT CAPILLARY TUBE 2 (6.0)(6.0) REFRIGERANT FLOW5/16CuT 5/32CuT5/16CuT 1/4CuT1/4CuT COOLING(8.0) (4.0)CAPILLARY TUBE 35/16CuT 5/32CuT(8.0) (4.0)M(6.0)PROPELLER FAN1/4CuT(12.0)(12.0)15/32CuT15/32CuT(12.0) (12.0)15/32CuT 15/32CuT(6.0)1/4CuT(12.0)15/32CuTFIELD PIPINGMUFFLER(8.0) (1/4 CuT)1/4CuT5/16CuT (6.0) (6.4)MUFFLER (8.0)(12.0)5/16CuT15/32CuTACCUMULATOR FIELD PIPING(1/2 CuT)(12.7)COMPRESSOR UNIT = INCH (mm)OUTDOOR AIR TEMPERATURETHERMISTORHEATEXCHANGERTHERMISTORMUFFLERWITHFILTERMUFFLERWITHFILTERGAS STOP VALVEWITH SERVICE PORTLIQUID STOPVALVEDISCHARGE PIPETHERMISTORFOUR-WAYVALVENORMALLY:OFFMOTOR OPERATEDVALVE3D071266