ESIE12-06 Operation Flow ChartFunction and Control 472.2 Heating OperationPower supply ONInitialize electronic expansion valveInitialize micro-computerPreheating operation controlRemote controller ONoperation judgementOperation modejudgementCooling/Dry HeatingEmergencyoperationThermostat ON judgementStarting controlfour way valve changeoverHot start control· Compressor step control· Electronic expansion valve PI control· Low pressure protection control· High pressure protection control· Heating overload control· Suction pipe superheat protection control· Discharge pipe temperature protection control· Inverter current protection control· Overall current protection control· Simulated operationNormal controlDefrostingconditionDefrostoperationDefrostendingjudgementHot startcontrolRemotecontroloperation OFFjudgementStandbyjudgementAbnormalstopjudgementThermostat OFF judgementRoom thermostat controlThermostat OFF by outdoortemperatureRestart standbyABBACooling/Dry EmergencyError codeindicationFour way valvechangeoverHeatingFour way valvechangeoverPump down residual operation